Mode 14: Dome light delay
Description: Keeps dome light on for 30 seconds after ignition is turned off
Connections:
Interface wiring
Pin 3 (White)
Pin 4 (Pink)
Pin 5 (Orange)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 10 (Gray)
To
Ground
Ground
Ground
Negative 30 second output (500 mA max)
Negative 30 second output (500 mA max)
Positive 30 second output (2 amp max)
Accessory or ignition from vehicle