Epson AcuLaser C8500 Quick Reference Manual - Page 4
Browse online or download pdf Quick Reference Manual for Printer Epson AcuLaser C8500. Epson AcuLaser C8500 21 pages. Epson aculaser c8500: quick start
Also for Epson AcuLaser C8500: Unpacking Manual (20 pages)
9.
Turn the toner cartridge knob 90 degrees clockwise
so that the N symbol on the knob is in the position
shown below. By turning the knob, the cartridge is
pressed into the slot and installed completely.
c
Caution:
Be sure to turn the knob all the way to the locked
position. Otherwise, you may have toner
problems or leakage.
10. If you need to replace another toner cartridge,
repeat steps 3 to 9.
11. Close the front cover.
Replacing the photoconductor unit
When you purchase a photoconductor unit, it always
comes with a waste toner collector because it usually
needs replacement at the same time as the
photoconductor unit. However, the waste toner
collector is also sold individually as you may need to
replace it separately depending on use.
Follow these steps to replace the photoconductor unit:
1.
Turn off the printer.
2.
Open the front cover.
3.
Turn the large lever 90 degrees counterclockwise.
4.
Turn the small lever to the right.
5.
Pull the photoconductor unit about 20 cm out of the
printer.
6.
Hold the handle at the top of the photoconductor
unit and gently pull it all the way out.
4 4 4 4