Arcflash Labs EMG-02 User Manual - Page 16

Browse online or download pdf User Manual for Industrial Equipment Arcflash Labs EMG-02. Arcflash Labs EMG-02 18 pages. 10 stage automatic coilgun

Arcflash Labs EMG-02 User Manual
3. Once the charging indicator light turns solid, the battery is fully charged and can be
removed from the charging unit.
4. Software
The software in this device is not intended to be user-serviceable. In fact, tampering with the EMG-
02 software is expressly discouraged and will immediately void any express or implied warranties. Any
attempt to modify the software may render the gun unusable or unsafe. Arcflash Labs, LLC assumes
absolutely no responsibility for units which have had their software modified by the end user.

5. Hardware Specifications

Accelerator Specifications
Primary power source
Power supply
Capacitors
Switches
Projectile
Magazine Capacity
Battery Capacity
Rate of fire
Muzzle velocity
Muzzle energy
Range
Efficiency
Physical Dimensions
Barrel length
Bore
Physical Dimensions
Overall Weight
(unloaded, no battery)
1x 15S Li-Ion – 63V
Proprietary (11kW)
1x 0.33F MV electrolytic
Proprietary (IGBT-based)
variable caliber, alloy steel, 4.6-8.5g
15-18 rounds
Up to 300 shots per battery
8.0 rounds/sec (auto) 13 rounds/sec (burst)
Up to 75 m/s
Up to 20 J
15 – 25 m (optimal/max)
4.45%
13.0"
0.32"
32.5" x 9.0" x 4.5"
9.7 lbs
Charging indicator
16 |
P a g e