8. Press ENT to end the sequence.
Note: The controller can store sixteen separate e-key Remotes, using different buttons
on each. An attempt to record a seventeenth remote will be ignored.
To program the other features, refer to the Quick Guide section at the end.
Normal Operation
Standard (Residential) Type
Assuming the gate is closed, when the controller receives a command from a
remote control, the gate will start opening, ramp up to full speed, and ramp down to
stop in the fully open position.
The gate may now be closed using the remote control, or it may be left to Auto-
close, if selected. The gate will close, ramping up and ramping down to stop in the
closed position.
Whilst the gate is opening or closing, a further command will cause it to stop.
If the gate is obstructed while closing, the gate will stop, reopen at slow speed and
bump the open rail-stop to re-calibrate itself.
If the gate is obstructed while opening, the gate will simply stop. When the gate next
closes, it will do so at slow speed and bump the closed rail-stop to re-calibrate itself.
Commercial Type
If selected as a Commercial Type, the controller regards all signals from remote
controls as dedicated 'Open' commands, thus avoiding the conflict that arises in a
multi-user situation.
If required, separate buttons for Open, Stop and Close may be installed, for instance,
in a guard-room.
Manual Over-ride
If it should be necessary to use the gate manually, slide the key-cover open, unlock
and pull the Manual over-ride lever. The gate may now be operated manually.
When the Manual over-ride lever is re-engaged, the motor will immediately start
closing the gate at slow speed to re-establish the closed position. Normal operation
will then continue.
5