OPERATING and MAINTENANCE INSTRUCTIONS
Models: 120PH, 121PH and 126 PH Series Proof/Hot Cabinets
HOW TO CLEAN UNIT:
DOOR
(Polycarbonate)
CABINETS
Inside and Outside
(Aluminum)
TROUBLE-SHOOTING CHART:
FAILURE
1. Indicator lights do NOT light.
2. Unit does not heat.
3. Unit gets too hot or won't shut off.
4. Humidity is low
5. Blower does not work or makes noise.
NOTE: Optional digital thermometer will flash if cabinet temperature is below 140°F or above 250°F.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
SOIL
Mild detergent* and water.
Dirt
Weak, alcohol-type cleaner.
Grease and Oil
Mild detergent* and hot water,
or mild abrasive cleaner.
Dirt
Steam (No strong alkaline
additive).
Chemical oven cleaner for
Fingerprints,
aluminum. Mild abrasive
Grease and Oil
cleaner; oily or waxy cleaner.
Mild abrasive cleaner, Oily or
Water Spots
waxy cleaner.
*Mild detergents include soaps and non-abrasive cleaners.
Call the factory if you need different settings.
CLEANER
POSSIBLE CAUSE
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet or cabinet.
1c. Switch is "OFF".
2a. Thermostat set too low or is "OFF".
2b. Switch is "OFF".
3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4a. Water in pan may be low
4b. Thermostat set too low
5a. Defective blower.
Proof/Hot
FL-2212
Cabinets
Rev. 8 (3/12)
Page 3 of 4
METHOD
1. Wipe with soft, damp cloth.
2. Rinse well.
1. Wipe with soft, damp cloth.
2. Rinse well.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry.
1. Rinse after steam cleaning.
2. Wipe dry.
Follow oven cleaner
manufacturer's directions.
Apply with clean, soft cloth.
Apply with soft, clean cloth.
Wipe with damp cloths.