ARCHPOT AWEIS Installation And Operation Manual - Page 5

Browse online or download pdf Installation And Operation Manual for Outdoor Fireplace ARCHPOT AWEIS. ARCHPOT AWEIS 12 pages. Apf burner system

ARCHPOT AWEIS Installation And Operation Manual
Product
Installation
WARNING! This unit is for outdoor use only.
• Do not install near any combustibles such as wood structures, fuels, clothing, fabrics, or dry vegetation.
• Installation shall be performed by a licensed contractor. All aspects of installation must conform
to local or national codes, or in the absence of codes, with Natural Fuel Gas Code ANZI Z223.1.
• An approved gas valve or keyed valve shall be installed in the decorative bowl or upstream of the unit
and located in an accessible area that is within 5ft from the AWEIS System.
Note: All AWEIS Systems includes pre-installed key valve, unless otherwise specified.
• The approved gas valve must be located where they can be easily accessible so that the gas can be shut
off quickly in case of an emergency.
Installation
1. Install the Fire Feature as shown in Figure 1 and Figure 2.
2. 24"- 60" Geo Round, 24"- 48" Legacy Round, 24"- 36" Geo Square, 30"- 36" Legacy Square requires
installation of the APF Mounting Bracket to secure the vessel and allow for ventilation and drainage.
Install the mounting bracket as shown in Figure 1. The mounting bracket should be secured using
supplied anchor bolts. Place the bolts through pre-drilled holes in GFRC vessel. Do not seal open space
between mounting bracket and vessel. Warranty is voided if the mounting bracket is not installed.
Figure 1
APF MOUNTING
BRACKET
NOTE: Drainage MUST be provided in the bottom of each bowl.
ANCHOR BOLTS
GFRC VESSEL
5