HOW TO ADJUST DOOR LATCH:
1. For vertical adjustment:
(up and down movement)
a. Loosen (2) screws located in magnetic
strike
b. Move strike up or down for alignment to
magnet on latch.
c. Tighten screws to secure.
2. For horizontal adjustment:
(greater or lesser magnetic draw)
a. Loosen (4) screws in door latch.
b. Move latch forward or backward to adjust
magnetism.
c. Tighten screws to secure.
HOT UNIT REMOVAL:
1.
Disconnect power cord from wall outlet.
2.
Remove screws around top cover.
3.
Disconnect the yellow cord between top and
bottom, in the back of the cabinet (see Figure 2).
4.
Lift off Hot Unit.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com