5925 Heisley Road • Mentor, OH 44060-1833
OPERATING and MAINTENANCE INSTRUCTIONS
Models: H137WSRR-C Series Companion Holding Cabinet
HOW TO HOLD:
1.
No water is needed in pan.
2.
Push POWER switch to "ON." Yellow POWER
LIGHT will come on.
3.
Push the "SET" button on the TEMPERATURE
CONTROL. The TEMPERATURE DISPLAY will
show "SP1" (set point 1).
4.
Press "SET" again and the current set point temperature
will be displayed.
5.
Press the
ADJUST buttons to adjust to the
desired temperature.
6.
Press "SET" to save the temperature setting.
7.
Preheat cabinet for 45 minutes.
8.
Put product into cabinet.
NOTES: Proper food holding temperature is 140°F/60°C or higher.
SOME TYPICAL THERMOSTAT SETTINGS:
Thermostat Setting
Air
Humidity
150° F
Off
175°F
Off
200°F
Off
100°F
150°F
Low
150°F
Med
150°F
High
160°F
Low
Note: These settings are based on laboratory conditions and may differ from conditions at point of use. Experiment with
the settings to determine what is best for your application.
Figure 3
Air is VERY HOT when door is opened.
Result
Cab. Temp.
Humidity
150° F
N/A
175° F
N/A
200° F
N/A
100°F
98%
115° F
98%
150° F
95%
150° F
95%
160° F
30%
Holding Cabinet
HOLD WITH HUMIDITY:
1.
Fill water pan with HOT water.
2.
Push POWER switch to "ON." Yellow POWER Light
will come on.
3.
Push the "SET" button on the TEMPERATURE
CONTROL. The TEMPERATURE DISPLAY will
show "SP1" (set point 1).
4.
Press "SET" again and the current set point temperature
will be displayed.
5.
Press the
ADJUST buttons to adjust to the desired
temperature.
6.
Press "SET" to save the temperature setting.
7.
Turn the "HUMIDITY" thermostat to No. 9.
8.
Preheat for 45 minutes.
9.
Turn "AIR" thermostat to desired temperature. (See
thermostat settings below.
10. Put product into cabinet
Thermostat Setting
Air
Humidity
160°F
Med
160°F
High
170°F
Low
170°F
Med
170°F
High
170°F
Max
200°F
Low
200°F
Med
200°F
High
Companion
FL-2330
Rev. 0 (2/07)
Page 3 of 10
Result
Cab. Temp
Humidity
160°F
160°F
170°F
170°F
170°F
170°F
200°F
200°F
200°F
50%
95%
15%
35%
85%
90%
7%
15%
40%