Digiplex EVO DGP2-ANC1B Instructions
Browse online or download pdf Instructions for Control Unit Digiplex EVO DGP2-ANC1B. Digiplex EVO DGP2-ANC1B 2 pages. Annunciator module
Annunciator Module V1.1
(DGP2-ANC1B)
Instructions
DGP2ANC1-EI02
P
M
ROGRAMMING
ETHOD
To program the DGP2-ANC1B, you must enter the Module Programming Mode
using any keypad in the system. To do so:
[0]
1.
Press and hold the
key.
[
]
2.
Enter the
INSTALLER CODE
[4003]
3.
Enter section
.
4.
Enter the Annunciator's 8-digit
5.
Enter the 3-digit section you wish to program.
Program the DGP2-ANC1B using the WinLoad Software or the control panel's
Module Broadcast feature. Refer to the Digiplex EVO Programming Guide for
more details.
*Note: The serial number is located on the module's PC Board.
Partition Assignment
Use this option to assign access to partitions. The DGP2-ANC1B will only
display the status of events that occur in partitions that have been assigned. For
example, if zone 5 in partition 1 has been breached, but partition 1 is not
assigned to the DGP2-ANC1B, zone 5 will not be displayed. Keys
represent partitions 1 through 8 respectively*. To assign access to a partition,
enable the option that corresponds to the desired partition. Partitions 1 to 8 are
enabled by default.
[1]
ON = Partition 1
[5]
ON = Partition 5
[2]
ON = Partition 2
[6]
ON = Partition 6
[3]
[7]
ON = Partition 3
ON = Partition 7
[4]
[8]
ON = Partition 4
ON = Partition 8
Beeper Mute Mode
[1]
Enable option
in section [002] to mute options
option to enable the use of options
Beep on System Trouble
Enable option [2] in section [002] to set the Annunciator to emit an intermittent
trouble beep* every three seconds. Troubles may be:
AC Failure
Battery Trouble
Aux. Current Limit
Bell Current limit
[1]
[002]
*Note: Option
in section
Beep on Communicator Trouble
[3]
[002]
Enable option
in section
I
NTRODUCTION
The Annunciator Module (DGP2-
ANC1B) is a status display device
that is connected to the control
panel's four-wire combus as a stand-
alone module or mounted on a
keypad. Set the DGP2-ANC1 to
display the status of up to eight
partitions, zones 1 to 48 or zones 49
to 96.
LED F
EEDBACK
Slow flash* Zone Alarm
Fast flash
Zone Tamper
Flash System not ready
ON
System ready
*
LED flashes until the partition in alarm
is disarmed
.
[
]
*.
SERIAL NUMBER
Section [001] - Option [1] to [8]
Section [002] - Option [1]
[2]
[5]
to
. Disable the mute
[2]
[5].
to
This option is disabled by default.
Section [002] - Option [2]
Bell Absent
ROM Check Error
RAM Check Error
Clock loss
must be disabled.
Section [002] - Option [3]
to set the Annunciator to emit a beep* when
these troubles occur:
TLM1
Fail to Communicate 1
Fail to Communicate 2
*Note: Option
Beep on Network/Module Trouble
Enable option
these troubles occur:
Module Tamper
Module ROM Check Error
Module Fail to Communicate
Printer Trouble
Module AC Failure
Module Battery Failure
*Note: Option
Zone Trouble
Enable option
these troubles occur:
Zone Tamper
Low Battery on Wireless Device
Zone(s) affected by: communication, fire loop, or CleanMe™ trouble
*Note: Option
The trouble beep will stop when the problem is resolved, or if you
press the
Section [002], options [2] to [5].
Status Display Mode
Enter a value between 000 and 005 in section [003] to set which status the
Annunciator will display.
000 = Partition Status (default)003 = Future Use
001 = Future Use
002 = Future Use
[1]
to
[8]
S
PECIFICATIONS
Input Voltage:
Compatibility:
Current Consumption:
B
I
EFORE
Choose a position where you will mount the Annunciator either as a stand-alone
module unit (see "Mounting as a Stand-alone Module"), or mounted on a keypad
(see "Mounting to a Keypad"). Once the module is connected and programmed,
you can use one of three display labels to reflect the DGP2-ANC1B's status
display. Should the system require more than one display, you can "stack" up to
three DGP2-ANC1Bs.
Do not remove the DGP2-ANC1B's guide clip (Figure 1) unless it is
mounted as a stand-alone module. This clip sets the distance between
the DGP2-ANC1B and the keypad or other Annunciators (if they are
"stacked"). If the clip is removed the DGP2-ANC1's covers cannot be
placed properly.
Mounting to a Keypad
1.
Connect one end of the wires to the Annunciator's network terminals. Do not
close the back and front covers until you have decided how you will set the
module.
2.
From the keypad's back plate, cut out section labelled "E" as shown in
Figure 2 on page 2.
3.
Loosen keypad's network terminal screws without disconnecting the wires.
4.
From the Annunciator's backplate, cut out section labelled "A" as shown in
Figure 1 on page 2.
[1]
[002]
in section
must be disabled.
[4]
[002]
in section
to set the Annunciator to emit a beep* when
[1]
[002]
in section
must be disabled.
[5]
[002]
in section
to set the Annunciator to emit a beep* when
[1]
[002]
in section
must be disabled.
[
]
key from any keypad on the network. This applies to
TRBL
004 = Zones 01 to 48
005 = Zones 49 to 96
Typically 11-16Vdc
EVO48, EVO192
DGP48, DGP848
DGP-NE96, EVO96
WinLoad V2.10 or higher
Min:15mA Typ:50mA Max:100mA
DGP2-ANC1B
NSTALLING THE
Fail to Communicate 3
Fail to Communicate 4
Fail to Communicate PC
Section [002] - Option [4]
Module Supply Output
Missing Keypad
General Failure
Network Overload
Network Com. Error
Missing Module
Section [002] - Option [5]
Section [003]