Cisco AP776A - Nexus Converged Network Switch 5020 Release Note - Page 34

Browse online or download pdf Release Note for Switch Cisco AP776A - Nexus Converged Network Switch 5020. Cisco AP776A - Nexus Converged Network Switch 5020 44 pages. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Also for Cisco AP776A - Nexus Converged Network Switch 5020: Release Note (48 pages), Release Note (26 pages), Release Note (22 pages), Quick Reference Manual (14 pages), Release Note (3 pages), Release Note (26 pages)

Cisco AP776A - Nexus Converged Network Switch 5020 Release Note
Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
CSCse31881
Symptom: If there are IP over Fibre Channel (IPFC) interfaces configured on an SSM, you might
experience issues if you downgrade from SAN-OS Release 3.x to Release 2.x.
Workaround: This issue is resolved.
CSCsg19148
Symptom: Time zone changes that are executed on an MDS switch do not take effect on the 12-port,
24-port, and 48 port 1-Gbps/2-Gbps/4-Gbps Fibre Channel modules, and on the 4-port 10-Gbps
module. This issue occurs in SAN-OS Releases 3.0(1), 3.0(2), 3.0(2a), and 3.0(3).
Time zone changes that are executed on an MDS switch do not take effect on the 16-port or 32-port
1-Gbps/2-Gbps module, on the 4-port or 8-port Gigabit Ethernet IP services module, the MPS-14/2
module, and on the SSM. This issue occurs in SAN-OS Release 3.0(3).
This issue has no effect on functionality. However, debug messages and syslogs from the MDS
switching modules have incorrect timestamps if the time zone is configured on an MDS switch.
Workaround: This issue is resolved.
CSCsg19303
Symptom: Graceful shutdowns of ISLs are not supported for IVR traffic.
Workaround: This issue is resolved.
CSCsk35951
Symptom: In a configuration with a PortChannel with FCIP members and write acceleration in use,
if IVR NAT is enabled on one end of the PortChannel and not enabled on the other end, then traffic
over the FCIP tunnel might fail.
Workaround: This issue is resolved.
CSCsk63929
Symptom: If DMM is provisioned on the SSM and you downgrade to a Cisco MDS SAN-OS release
that does not support DMM, the configuration persists and the GUI and CLI show DMM as a
provisioned application.
Workaround: This issue is resolved.
CSCsk87502
Symptom: If an NASB configuration in a VSAN is destroyed while a target discovery is pending,
the NASB process fails. Issue the show nasb vsan x command on the SSM to view the target
discovery in the Pending state.
Workaround: This issue is resolved.
CSCsk93834
Symptom: In rare situations during a storage-based online data migration job, the user might not be
able to destroy the job if the following sequence of events occurs:
Workaround: This issue is resolved.
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
34
A storage-based data migration job is executing.
1.
A port flap occurs on the server and the server HBA port goes down.
2.
The storage-based data migration job continues executing until it completes.
3.
The user issues the dmm module module-id job job-id destroy command to delete the
4.
storage-based data migration job, but the delete fails.
OL-14116-11