Cisco AP776A - Nexus Converged Network Switch 5020 Release Note - Page 37

Browse online or download pdf Release Note for Switch Cisco AP776A - Nexus Converged Network Switch 5020. Cisco AP776A - Nexus Converged Network Switch 5020 44 pages. Cisco nexus 5000 series release notes release 4.1(3)n1(1) (ol-16601-01 h0, july 2009)
Also for Cisco AP776A - Nexus Converged Network Switch 5020: Release Note (48 pages), Release Note (26 pages), Release Note (22 pages), Quick Reference Manual (14 pages), Release Note (3 pages), Release Note (26 pages)

Cisco AP776A - Nexus Converged Network Switch 5020 Release Note
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Note
Workaround: This issue is resolved.
CSCso63465
Symptom: FCP-CMD (for example, Inquiry) frames targeted to LUN 0x45F0 or LUN 0x50F0 are
dropped by an MDS switch when traffic flows (egresses) through Generation 2 modules. LUN
0x45F0 corresponds to HPUX Volume Set Address <VBUS ID: 0xB, Target ID: 0xE, LUN: 0x0>.
Workaround: This issue is resolved.
CSCsq54455
Symptom: On a DS-X9032 module where the SRAM parity error was seen, the SRAM parity error
exceptions were logged continuously.
Workaround: This issue is resolved.
CSCsq57352
Symptom: After upgrading from Fabric Manager Release 3.0(2a) to Fabric Manager
Release 3.2(3a), the Fabric Manager client fails to reuse the map layout files produced by Release
3.0(2a). Renaming the map layout files will make them compatible with Fabric Manager Release
3.2(3a).
Workaround: This issue is resolved.
CSCsq66823
Symptom: On an MDS 9222i switch, an upgrade from SAN-OS Release 3.2(x), Release 3.3(1a), or
Release 3.3(1c) to SAN-OS Release 3.3(1c) fails when there is an active FC-Redirect configuration
(created by SME or DMM applications) on the switch. An active FC-Redirect configuration is
defined as:
If an upgrade is attempted when an active configurations is present, the switch will go into a
disruptive upgrade.
Workaround: This issue is resolved.
CSCsr90831
In rare instances, the following Generation 2 modules and MDS switches might reload:
OL-14116-11
This applies only to Terminal Server running in Application Mode. This issue does not affect
users running a Terminal Server or Remote Desktop session in Remote Administration
mode.
FC-Redirect configuration for hosts or targets connected locally
FC-Redirect configuration created by the application running on that switch.
MDS 900012-port 4-Gbps Fibre Channel switching module
MDS 9000 24-port 4-Gbps Fibre Channel switching module
MDS 9000 48-port 4-Gbps Fibre Channel switching module
MDS 9000 4-port 10-Gbps Fibre Channel switching module
MDS 9124 Multilayer Fabric Switch
Cisco Fabric Switch for HP c-Class BladeSystem
Cisco Fabric Switch for IBM BladeCenter
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
Caveats
37