FIBARO CO Sensor FGCD-001 Operating Manual - Page 6
Browse online or download pdf Operating Manual for Accessories FIBARO CO Sensor FGCD-001. FIBARO CO Sensor FGCD-001 17 pages. Co
6
i
NOTE
Recommended height
of installation is de-
pendant on the pur-
pose of the room and
height at which head
typically is.
PHySICAL INSTALLATION
#4: Physical installation
READ BEFORE INSTALLATION
!
AND HEED ALL THE WARNINGS!
The device should be installed below the ceiling level.
•
•
The device should be installed on the wall, at least 30 cm (1 ft) away
from the corners.
•
The device should not be installed: in a bathroom, next to heat
sources, within range of kids, obstructed from possible carbon
monoxide sources, in direct sunlight.
The device should be installed by a qualified installator.
•
Do not paint the device.
•
The device should be cleaned with a slightly damp cloth or mois-
•
tened tissue.
Place of installation:
NOT HERE
Installation on the wall:
1.
1. Mount the cover on a wall.
2. Attach the device to its cover.
3. Turn the device clockwise to close it.
CEILING
30cm/1ft
WALL
HERE
1.5m/5ft
FLOOR
2.