7: Advanced parameters
The device allows to customize its operation to user's needs using
configurable parameters. The settings can be adjusted in the FIBARO
for HomeKit app.
Available parameters:
aDVanceD parameters
1.
This parameter determines how the device will
Description
react in the event of power supply failure (e.g.
power outage or switching off the main fuse).
Default value
2
0 - device remains off
Available
1 - device returns to white on full brightness
values
2 - device restores the state from before the
power cycle
2.
This parameter determines which program of
Description
the preprogrammed lighting programs is cur-
rently active.
Default value
0
Available
1–18 - the number of the program
values
3
This parameter determines the order of the con-
Description
nected channels and the type of the strip.
Default value
"BRGW"
String value representing RGBW channels, i.e. 'B'
Available
'R' 'G' 'W' in an order corresponding to the actual
values
connection. The colors should be listed from the
power supply side pin.
4.
This parameter defines the type of auto-off
Description
mode.
Default value
1
0 - auto-off mode disabled
Available
1- device will turn off once after the set time
values
2 - device turns off after the set period of time
each time it is switched on
Device state after power cycle
Active program
RGBW channels configuration