Sharp Carousel II R-3A54 Service Manual - Page 14

Browse online or download pdf Service Manual for Microwave Oven Sharp Carousel II R-3A54. Sharp Carousel II R-3A54 36 pages. Microwave oven
Also for Sharp Carousel II R-3A54: Operation Manual (27 pages)

R-3A54
R-3E54
TEST PROCEDURES
(CONT'D)
PROCEDURE
LETTER
COMPONENT
TEST
I
LIVE TEST FOR MOTOR
WINDINGS
CAUTION:
The following
procedure
requires
the oven to be connected
to the supply
and should
only be used if the relevant
"cold"
checks
for the motor
un-
der test are inconclusive.
1. CARRY OUT3JCHECKS
2. Disconnect
the leads from the primary
of the power transformer.
Make sure that the leads
remain isolated from other oven components
and chassis. (Use insulation
tape if necessary,)
3. Connect
a voltmeter,
set to 250V AC, across the motor terminals.
(Refer to the relevant motor
test procedure
or pictorial
diagram for the correct terminal
numbers.)
4. Arrange the meter in a position
where it can be read during the test. (Do not touch the meter,
meter leads or oven circuitry
while the oven is active.)
5. Close the oven door.
6. Set the relevant timer for about three (3) minutes,
set the power level to HIGH and push the
START button.
7. Note the reading on the meter and carefully
observe the motor under test to see if it is turning.
8. CARRY OUT 3D CHECKS
9. Remove test meter leads.
1 O.Reconnect
the leads to the primary of the power transformer.
If a reading of 240 volts AC was obtained
(step 7) but the motor was not turning
then it is faulty
and should
be replaced.
If the meter indicated
that no supply was present then the wiring
to the
motor should
be checked for continuity.
J
BLOWN
FUSE
F M8A
CARRY OUT 3D CHECKS
1. If the fuse M8A is blown,
there could be a shorts or ground
in electrical
parts or wire harness.
Check them and replace the defective
parts or repair the wire harness.
2. If the fuse M8A
is blown
when
the door is opened,
check the 1st latch switch,
2nd latch
switch,
monitor
switch
and monitor
resistor.
If the fuse M8A is blown
by incorrect
door switching
replace the defective
switch(s)
and the
fuse M8A.
3. If the fuse M8A is blown,
there could
be a short in the asymmetric
rectier or there could
be
a ground
in wire harness.
A short in the asymmetric
rectifier
may have occured
due to short
or ground
in H.V. rectifier,
magnetron,
power transformer
or H.V. wire.
Check them and re-
place the defective
parts or repair the wire harness.
CARRY OUT 4J CHECKS
CAUTION:
Only
replace
fuse with
the correct
value
replacement.
K
TOUCH
CONTROL
PANEL
ASSEMBLY
TEST
The touch
control
panel consists
of circuits
including
semiconductors
such as LSI, ICs, etc.
Therefore,
unlike conventional
microwave
ovens, proper maintenance
cannot
be performed
with
only a voltmeter
and ohmmeter.
In this service manual, the touch control
panel assembly
is di-
vided into two units, Control
Unit 'and Key Unit, and troubleshooting
by unit replacement
is de-
scribed according
to the symptoms
indicated.
1. Key Unit.
The following
symptoms
indicate
a defective
key unit. Replace the key un t.
a)
When touching
the pads, a certain pad produces
no signal at all.
b) When touching
a number pad, two figures or more are displayed.
c)
When touching
the pads, sometimes
a pad produces
no signal.
2. Control
Unit
The following
symptoms
indicate
a defective
control
unit, Replace the COI
2-l
In connection
with
pads.
trol unit.
a)
When touching
the pads, a certain group of pads do not produce
a signal.
14