Sharp Carousel R-1201 Service Manual - Page 20
Browse online or download pdf Service Manual for Microwave Oven Sharp Carousel R-1201. Sharp Carousel R-1201 40 pages. Over the counter microwave oven
Also for Sharp Carousel R-1201: Brochure & Specs (8 pages), Operation Manual & Installation Instructions (32 pages)
R-1200
R-1201
PROCEDURE
LETTER
8) Disconnect the power supply cord.
9) Open the door and block it open.
10) To discharge high voltage capacitor, wait for 60 seconds.
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
The touch control section consists of the following units
as shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit (The Control unit consists of LSI Unit and
Power Unit)
The principal functions of these units and the signals com-
municated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through P20, P21, P22, P23,
P24, P25, P26 and P27.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through P43, P44,
P45 and P46 to perform the function that was requested.
Control Unit
Control unit consists of LSI, power source circuit, synchro-
nizing signal circuit, reset circuit, buzzer circuit, relay circuit
indicator circuit and back light circuit.
1) LSI
This LSI controls the key strobe signal, relay driving
signal for oven function and indicator signal.
2) Power Source Circuit
This circuit generates voltages necessary for the control
unit from the AC line voltage.
In addition, the synchronizing signal is available in order
to compose a basic standard time in the clock circuit.
TEST PROCEDURES
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
COMPONENT TEST
Symbol
Voltage
VC
-5.3V
3) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It incorporates a very small error because it works
on commercial frequency.
4) Reset Circuit
A circuit to generate a signals which resetting the LSI to
the initial state when power is applied.
5) Buzzer Circuit
The buzzer is responds to signals from the LSI to emit
audible sounds (key touch sound and completion sound).
6) Door Sensing Switch
A switch to inform the LSI if the door is open or closed.
7) Relay Circuit
To drive the magnetron, fan motor, turntable motor and
light the oven lamp and hood lamp.
8) Indicator Circuit
This circuit consists of 22 segments and 3 common
electrodes using a Light Crystal Display.
9) Back Light Circuit
A circuit to drive the back light (Light emitting diodes LD1-
LD4).
18
Application
LSI(IC1)