Digistar 410002 Installation Manual - Page 5

Browse online or download pdf Installation Manual for Measuring Instruments Digistar 410002. Digistar 410002 9 pages. Rotation counter for ez/tmr xx10 series indicators

INSTALLATION INSTRUCTIONS

The Rotation Counter Sensor can be installed on any shaft or sprocket that is directly coupled to the
mixer's primary mixing rotor or auger.
If the mixer is equipped with a transmission or gearbox that provides a neutral or de-coupled setting the
Rotation Counter must be installed downstream on the mixing rotor or auger side of the transmission or
gearbox.
The Rotation Counter can also be installed to directly sense the rotations of the primary mixing rotor or
auger if accessible.
To install on a PTO Input Shaft:
1. Clean PTO shaft with wire brush where applying target and wipe down with cleaning agent.
2. Peel off adhesive backing on target.
3. Attach target, adhesive side down, securely to PTO shaft with hose clamp as shown in Figure 2. Place
hose clamp screw head inside target as shown in Figures 3.
The installation diagrams show safety shields removed in order to show additional details. Never
operate equipment without safety shields in place. Adding the target to a rotating shaft may require additional
shielding and is not provided. Consult your original equipment manufacturer.
D4044
Rotation Counter Installation Manual for EZ/TMR xx10 Series Indicators
Figure 2: Target Installation
Installation Instructions
5