Sharp 14BM2G Service Manual - Page 25

Browse online or download pdf Service Manual for TV Sharp 14BM2G. Sharp 14BM2G 40 pages.

DESCRIPTION OF SCHEMATIC DIAGRAM

SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE
REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS
POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OP-
ERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH " å " (
MAINTAINING THE SAFETY OF THE SET. BE SURE TO RE-
PLACE THESE PARTS WITH SPECIFIED ONES FOR MAINTAIN-
ING THE SAFETY AND PERFORMANCE OF THE SET.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE (
CONNECTED WITH AC MAINS VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANS-
FORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE
HAZARD OF ELECTRIC SHOCK.
) ARE IMPORTANT FOR
) IS DIRECTLY
27
NOTES:
1. The unit of resistance "ohm" is omitted.
(K = 1000 ohms, M = Meg ohm).
2. All resistors are 1/16 watt, unless otherwise noted.
3. Unit of all capacitors are F with prefix symbol ( µ, P, ETC) .
VOLTAGE MEASUREMENT CONDITIONS:
1. Voltage in parenthesis measured with no Signal.
2. Voltages without parenthesis measured with PAL Colour-Signal.
3. All the voltages in each point are measured with high impedence
volt-meter.
WAVEFORM MEASUREMENT CONDITIONS:
1. Colour bar generator signal of 1.8V peak to peak applied at Base
of Video Buffer Amp. Q203.
2. Approximately 4.0 V AGC bias.
14BM2, 14BM2S/G
20BM2, 20BM2S/G
21BM2, 21BM2S/G