Caption position adjustment (horizontal)
1. Have unit receive a good local channel.
2. Enter the service mode and select service adjustment
"S18".
3. A black text box appears on the screen (see Figure
C ) .
4. Adjust "S18" data value so that text box is positioned
in the center of the screen.
Figure C.
3.58MHz trap adjustment
1. Have unit receive a good local channel.
2. Enter the service mode and select service adjustment
"S16" .
3. This is a two position adjustment, "00"is ON , "01" is
OFF.
4. Adjust data value to "00" for normal viewing.
Sharpness and Audio balance adjust-
ments
1. Have unit receive a good local channel.
2. Enter the service mode and select "S05" for
sharpness and "S17" for balance.
•
Sharpness adjustments
3. Adjust data value to "24" (center of data range) for
sharpness adjustment.
•
Audio balance adjustments
4. Adjust data value to "20" (center of data range) for
Audio balance adjustment.
5. Receive the following composite stereo signal2.
Stereo signal :30% modulation , left channel only,
noise reduction on, 3kHz.
6. Enter the service mode and select the service
adjustment "M05".
7. Adjust the data until theAC voltage reading of the
rms voltmeter is minimum.
8. Take the above steps 1 thru 8 again for fine
adjustment.
MTS level adjustment
1. Feed the following monaural signal to pin (14) of
IC3001.
Monaural signal: 300Hz,245mVrms
2. Connect the rms voltmeter to pin (39) of IC3001.
3. Enter the service mode and select the service
adjustment "M01".
4. Adjust the data so that the rms voltmeter should take
the reading below. Spec:490 ±10mVrms.
Stereo VCO adjustment
1. Keep the unit in no-signal state.
2. Connect the frequency counter to pin (39) of IC3001.
3. Connect a capacitor (100µ F, 50V) in between positive
(+) side of C3005 and ground.
4. Enter the service mode and select the service
adjustment "M02".
5. Adjust the data so that frequency counter should take
the reading below.Spec:62.94 ±0.75kHz
Filter adjustment
1. Feed the following stereo pilot signal to pin (14) of
IC3001.Stereo pilot signal:9.4kHz,600mVrms.
2. Enter the service mode and select the service
adjustment "M03".
3. Adjust the data at the point where "OK" appears on
the screen. The "OK" represents the approximate
center of the adjustable range of the data.
Separation Adjustment
1. Connect the rms voltmeter to pin (39) of IC3001.
2. Receive the following composite stereo signal 1.
Composite stereo signal: 30% modulation, left
channel only, noise reduction on, 300Hz.
3. Enter the service mode and select the service
adjustment "M04".
4. Adjust the data until the AC voltage reading of the
rms voltmeter is minimum.
11
20J-S100/100S
CJ20S10/21MJ50