PIN REF.
SIGNAL DESCRIPTION
PC1
MAINS INPUT (NEUTRAL)
M3-6
PC1
GROUND CONNECTION
M3-5
PC1
MAINS INPUT (PHASE)
M3-4
PC3
0V INSULATED
M2-4
PC3
START COMMAND INPUT
M2-3
(required current 10 mA)
PC3
+18V INSULATED
M2-1
OUTPU SUPPLY FOR VIBRATOR
PC2-1
(M3-1)
OUTPU SUPPLY FOR VIBRATOR
PC2-2
(M3-2)
PC2-3
SHIELD
(M3-3)
PC2-T
GROUND CONNECTION
(M3-3)
M2-9
CURRENT REFERENCE (0-20mA)
VOLTAGE REFERENCE (0-5V)
M2-8
M2-7
POTENTIOMETER CURSOR
M2-6
POTENTIOMETER MINIMUM
M2-5
POTENTIOMETER MAXIMUM
M2-4
0V INSULATED FOR REMOTE
COMMANDS
REMOTE START-STOP COMMAND
M2-3
M2-2
OUTPUT POWER SUPPLY OK
M2-1
+18V INSULATED FOR REMOTE
COMMANDS
Note:
The guts of the vibrator must be grounded with a appropriate wire.
Before supplyng the device verify that there are not ground dispersions on
wires connecting the power supply to the vibrator; The power supply will be
damaged if one of the two output wires is grounded.

WIRING TABLE

WIRE
SECTION
mmq
3x1
3x1
3x1
3x0, 5
shielded
3x0, 5
shielded
3x0, 5
shielded
3x1
shielded
3x1
shielded
3x1
shielded
3x1
shielded
0,35
0,35
0,35
0,35
0,35
0,35
0,35
0,35
0,35
5
WIRE
CONNECT TO:
COLOR
BLUE
230 Vac
YELLOW-
EARTH
GREEN
BROWN
230 Vac
VIBRATOR COIL
VIBRATOR COIL
YELLOW-
EARTH
GREEN
VOLTAGE REF.
CURSOR
COUNTERCLOCKWISE
CLOCKWISE
0V
PNP
+18V
N.C.