Digital Alert Systems R198 Instruction Manual - Page 7

Browse online or download pdf Instruction Manual for Switch Digital Alert Systems R198. Digital Alert Systems R198 13 pages. 4 unit aes switch

The green LED on the front panel indicates power is ON in the unit.
Unbalanced monaural or left unbalanced stereo audio is input from the EAS source on pins 1
and 2 of the XLR female connector in the MASTER section as shown on page 6. And, if
desired, right unbalanced stereo audio is input from the EAS source on pins 1 and 2 of the
XLR male connector in the Master section.
The AES digital stream is input on the female connector and output on the male connector for
each of the sections labeled 1 through 4.
Shorting pins 1 and 2 of the 3 pin Master connector will activate all four AES sections.
Shorting pins 9 and 10 on the screw terminal for each of the sections 1 through 2 will activate
that AES section of the device.
As referenced later in the manual, a browser that opens to the ethernet device in the unit may
also be used to activate any of the four AES sections.
In each of the four sections, a normal open dry contact closure is available on screw terminals
3 and 2.
Power from 90 to 240 VAC is input from the universal power cord connection. The local
ethernet cable RJ45 connector is plugged into the LAN socket.The audio input is switched into
the AES card, converted to an AES digital stream, and substituted for the program digital
stream via software command over the ethernet link from the DASDECII EAS Controller.
7