Crestron 6510420 Quick Start - Page 2
Browse online or download pdf Quick Start for Control Systems Crestron 6510420. Crestron 6510420 5 pages.

CP4/CP4N
4-Series Control System
Connect the Device
Make all necessary connections to the control system as shown below.
Observe the following when connecting the control system:
Use Crestron power supplies for Crestron equipment.
l
The control system may be powered with the included 24 VDC power
l
supply or via Cresnet® network power with the NET port.
Connect the chassis ground lug to a known earth ground circuit (such
l
as building steel) to ensure that the control system is grounded
properly.
Apply power after all connections have been made.
l
COM 1 Connections
Port
RS-232
G
GND
TX
TX (from CP4/CP4N)
RX
RX (to CP4/CP4N)
RTS
RTS (from CP4/CP4N)
CTS
CTS (to CP4/CP4N)
1. RS-422 transmit and receive are balanced signals that require two lines plus a ground
in each direction. RXD+ and TXD+ should idle high (going low at start of data
transmission). RXD- and TXD- should idle low (going high at start of data
transmission). If necessary, RXD+/RXD- and TXD+/TXD- may be swapped to maintain
correct signal levels.
2. A ground terminal connection is recommended but not required.
Quick Start
1
RS-422
RS-485
2
GND
GND
TX- (from CP4/CP4N)
TX-/RX-
RX+ (to CP4/CP4N)
Not used
TX+ (from CP4/CP4N)
TX+/RX+
RX- (to CP4/CP4N)
Not used
2