General Specifications

Electrical
Rated Voltage
Allowable Voltage
Range
Rated Frequency
Allowable Voltage Drop
Power Consumption
Voltage Endurance
Insulation Resistance
Environmental
Ambient Operating
Temperature
(Cabinet Interior)
Storage Temperature
Ambient Humidity
Air Purity Level
Pollution Degree
Atmosphere
Vibration Resistance
Noise Endurance
(Impulse Noise)
Electrostatic Discharge
Immunity
Noise Immunity
(First transient burst
noise)
(however, pause occurrences must be more than 1 second apart)
AC 1500V at 20mA for 1 minute
(between charging and FG terminals)
10M Ω or higher at DC 500V
(between charging and FG terminals)
o
o
5
C to 50
C (With HDD attached)
o
o
0
C to 50
C (Without HDD)
(Non condensing, wet blub temperature : 29
2
9.8m/s
at 10Hz to 25Hz in X, Y, Z directions for 30 minutes
With HDD attached : 4.9m/s
Pulse Duration: 50ns, 500ns, 1 µ s
Power Line : 2kV IEC 61000-4-4
COM Port : 1kV IEC6100-4-4
7
AC 100V/AC 240V
AC 85V to AC 265V
50/60Hz
1 cycle or less
110VA or less
o
o
-10
C to 60
C
10% RH to 85% RH
Free of dust
Pollution Degree 2
Free of corrosive gas
Noise Voltage: 1500V
Rise Time : 1ns
(via noise simulator)
6kV IEC 61000-4-2
o
C)
2