Bitstream HYPERION-402 Quick Start Manual - Page 4

Browse online or download pdf Quick Start Manual for Switch Bitstream HYPERION-402. Bitstream HYPERION-402 6 pages. Managed industrial ethernet switch

Quick start manual for
1.4
The optical ports are equipped with SFP slots and CU module with four dedicated SFP/SFP +
slots. The range and type of connector depends on the type of SFP insert. SFP slots support 100 and
1000 Mbit/s and SFP/SFP + slots support 1G/2.5G/10Gb.
SFP optical ports
Status signaling of
External LED – signals transmission link for 1Gbps (if activity – blinking)
Internal LED – signals transmission link for 100Mbps (if activity – blinking)
Range and type of connector depends on the type of SFP insert.
P
2
OWER SUPPLY
Supply voltage range:
version 7 – 36-60VDC power supply, for PoE in the range of 45-57VDC
version C – 80-360VDC or 75-270VAC power supply,
version 77p – 36-60VDC redundant power supply, for PoE in the range 45-57VDC
version CCp – 80-360VDC or 75-270VAC redundant power supply
75-270VAC power supply does not support PoE function
Optional two supply inputs – redundant
Screw block connectors for DC or AC power supply
Total power consumption (without PoE ports) - <50W
Power supply also have power LED indicator (for each power supply)
Screw for GND connection
The power supplies in the device are protected against inverted power polarity. In case of
reversing the polarity at the moment of connecting the power supply, the device will work.
3
POE POWER SUPPLY (A
Compliant with the IEEE802.3af standard, IEEE802.3at
For 45-57V DC power, the power available for each port up to 30 or 90W. (depending on
selected version)
For 55VDC power, the maximum total PoE power is 500W
F
4
IRST START
After connecting the power supply with appropriate parameters to the inputs, the PWR LED should
first light up, flashing alternately in two colours: orange and green, and then switch only to green. If
only one of the power supply inputs is used, only one PWR diode corresponding to this input will
light up.
The red "ERR" LED's indicating the status of the modules and start blinking, which indicates that
the device is starting up. When the "ERR" LED's do not light up, the switch is ready for operation.
The device can be managed using the recommended Ethernet NMI or RJ45 interface via the RS-
232 console.
D
5
EFAULT PARAMETERS
IP parameters:
Address: 192.168.0.10
User: admin
REV.
1.08
Description of SFP optical ports
DDITIONAL OPTION
-
UP
Mask: 255.255.255.0
Password: no password (empty)
SHORT USER MANUAL HYPERION-402
H-402
- www.bitstream.pl/ en/
)
2021.03.31
4/6