Siemens SIMATIC ET 200SP Product Information - Page 9

Browse online or download pdf Product Information for Industrial Equipment Siemens SIMATIC ET 200SP. Siemens SIMATIC ET 200SP 38 pages. Distributed i/o system
Also for Siemens SIMATIC ET 200SP: Manual (40 pages), User Manual (21 pages), Manual (34 pages), Manual (48 pages), Manual (30 pages), Manual (34 pages), Manual (37 pages), Manual (36 pages), Manual (44 pages), Manual (31 pages), Manual (35 pages), Manual (23 pages), Configuration Manual (20 pages), Manual (34 pages), Manual (29 pages), Manual (33 pages), Manual (31 pages), User Manual (32 pages), Manual (31 pages), Manual (28 pages), Manual (41 pages), Manual (32 pages), Manual (49 pages), Manual (24 pages), Manual (34 pages), Manual (41 pages), Manual (30 pages), Manual (31 pages), Manual (27 pages), Manual (24 pages), Manual (24 pages), Manual (25 pages), Manual (49 pages), Manual (40 pages), Manual (38 pages), Manual (39 pages), Product Information (24 pages), Manual (32 pages), Product Information (10 pages), Equipment Manual (43 pages), Manual (33 pages), Equipment Manual (44 pages), Original Operating Instructions (6 pages), Manual (35 pages), Manual (28 pages), Equipment Manual (32 pages), Manual (50 pages), Manual (30 pages), Manual (26 pages), Manual (28 pages), Manual (34 pages), Manual (44 pages), Manual (33 pages), Equipment Manual (42 pages), Original Instructions Manual (16 pages)

Siemens SIMATIC ET 200SP Product Information
SIMATIC Safety F-system with ET 200SP
The following figure shows a sample configuration for a SIMATIC Safety F-system with,
among other things, an ET 200SP on a PROFINET IO. The PROFINET IO lines can be set
up with copper cable, with fiber-optic cable or WLAN.
You will find further information on the Internet at Application planning (Page 13).
Tasks of the fail-safe IO controller (F-CPU) include the exchange of safety-related and non-
safety-related data with fail-safe and standard ET 200SP modules.
Figure 1-1
Use in safety mode only
Fail-safe modules can only be used in fail-safe mode. They cannot be used in non-fail-safe
mode In this context, fail-safe mode/non-fail-safe mode refers to the operating mode of the
F-I/O module, which either does or doesn't support safety-related communication via safety
message frames.
Fail-safe modules and non-fail-safe modules can be combined within an ET 200SP.
ET 200SP distributed I/O system
Product Information, 07/2013, A5E32288220-AA
1.1 What are fail-safe automation systems and fail-safe modules?
Fail-safe SIMATIC Safety automation system (sample configuration)
Product overview
9