Also for Siemens SIMATIC ET 200SP: Manual (40 pages), User Manual (21 pages), Manual (34 pages), Manual (48 pages), Manual (30 pages), Manual (34 pages), Product Information (38 pages), Manual (37 pages), Manual (36 pages), Manual (44 pages), Manual (31 pages), Manual (35 pages), Manual (23 pages), Configuration Manual (20 pages), Manual (29 pages), Manual (33 pages), Manual (31 pages), User Manual (32 pages), Manual (31 pages), Manual (28 pages), Manual (41 pages), Manual (32 pages), Manual (49 pages), Manual (24 pages), Manual (34 pages), Manual (41 pages), Manual (30 pages), Manual (31 pages), Manual (27 pages), Manual (24 pages), Manual (24 pages), Manual (25 pages), Manual (49 pages), Manual (40 pages), Manual (38 pages), Manual (39 pages), Product Information (24 pages), Manual (32 pages), Product Information (10 pages), Equipment Manual (43 pages), Manual (33 pages), Equipment Manual (44 pages), Original Operating Instructions (6 pages), Manual (35 pages), Manual (28 pages), Equipment Manual (32 pages), Manual (50 pages), Manual (30 pages), Manual (26 pages), Manual (28 pages), Manual (34 pages), Manual (44 pages), Manual (33 pages), Equipment Manual (42 pages), Original Instructions Manual (16 pages)

Siemens SIMATIC ET 200SP Manual
4.3

Address space

The module can be configured differently in STEP 7; see following table. Depending on the
configuration, additional/different addresses are assigned in the process image output/input.
Configuration options of DQ 4×24VDC/2A HF
You can configure the module with STEP 7 (TIA Portal) or with a GSD file. When you
configure the module by means of the GSD file, the configuration is available under different
abbreviations/module names. The following configurations are possible:
Table 4- 2
Configuration options with GSD file
Configuration
1 x 4-channel without value
status
1 x 4-channel with value status
1 x 4-channel with value status
for module-internal Shared
Output with up to 4 submodules
1 x 4-channel without value
status
1 x 4-channel with value status
1 x 4-channel with value status
for module-internal Shared
Output with up to 4 submodules
2 x 2-channel without value
status
2 x 2-channel with value status
Note
The following functions are only fully available when the submodule X.1 is configured and
the IO controller to which submodule X.1 is assigned has established a connection to the
IO device.
• Firmware update
• I&M identification data
• PROFIenergy
Digital output module DQ 4x24VDC/2A HF (6ES7132-6BF20-0CA0)
Manual, 12/2015, A5E32855695-AC
Abbreviation/module
name in the GSD file
DQ 4×24VDC/2A HF
V1.0
DQ 4×24VDC/2A HF
V1.0, QI
DQ 4×24VDC/2A HF
V1.0, MSO
DQ 4×24VDC/2A HF
V2.0
DQ 4×24VDC/2A HF
V2.0, QI
DQ 4×24VDC/2A HF V2.
0, MSO
DQ 4×24VDC/2A HF
V2.0, S.2
DQ 4×24VDC/2A HF
V2.0, S.2 QI
Configuration software, e.g. STEP 7 (TIA Portal)
Integrated in the
hardware catalog
PROFINET IO
STEP 7, as of
V13, SP1
X
X
X
---
---
---
---
---
Parameters/address space
4.3 Address space
GSD file
GSD file
PROFIBUS DP
X
X
X
---
X
---
X
---
X
X
X
---
X
---
X
---
17