Also for Siemens SIMATIC ET 200SP: Manual (40 pages), User Manual (21 pages), Manual (34 pages), Manual (48 pages), Manual (30 pages), Manual (34 pages), Product Information (38 pages), Manual (37 pages), Manual (36 pages), Manual (44 pages), Manual (31 pages), Manual (35 pages), Manual (23 pages), Configuration Manual (20 pages), Manual (34 pages), Manual (29 pages), Manual (33 pages), Manual (31 pages), User Manual (32 pages), Manual (31 pages), Manual (28 pages), Manual (41 pages), Manual (32 pages), Manual (49 pages), Manual (24 pages), Manual (34 pages), Manual (41 pages), Manual (30 pages), Manual (31 pages), Manual (27 pages), Manual (24 pages), Manual (24 pages), Manual (25 pages), Manual (40 pages), Manual (38 pages), Manual (39 pages), Product Information (24 pages), Manual (32 pages), Product Information (10 pages), Equipment Manual (43 pages), Manual (33 pages), Equipment Manual (44 pages), Original Operating Instructions (6 pages), Manual (35 pages), Manual (28 pages), Equipment Manual (32 pages), Manual (50 pages), Manual (30 pages), Manual (26 pages), Manual (28 pages), Manual (34 pages), Manual (44 pages), Manual (33 pages), Equipment Manual (42 pages), Original Instructions Manual (16 pages)

Siemens SIMATIC ET 200SP Manual
Address space of the AI 2×U/I 2-/4-wire HS for oversampling with one channel
The following figure shows the assignment of the address space for oversampling with one
channel. Writing always starts from IB x. If fewer than 16 sub-cycles are set, the addresses
that are then unused are filled with 7FFF
Figure 4-5
Address space of the AI 2×U/I 2-/4-wire HS for oversampling with two channels
The following figure shows the assignment of the address space for oversampling with two
channels. Writing always starts from IB x. Only a maximum of 8 sub-cycles are possible. If
fewer than 8 sub-cycles are set, the addresses that are then unused are filled with 7FFF
Figure 4-6
Analog input module AI 2xU/I 2-/4-wire HS (6ES7134-6HB00-0DA1)
Manual, 09/2018, A5E03576060-AF
Address space of AI 2xU/I 2-/4-wire HS for oversampling with one channel
Address space of AI 2xU/I 2-/4-wire HS for oversampling with two channels
.
H
Parameters/address space
4.5 Address space
H
.
25