Siemens SIMATIC RTLS PCB OEM PULSE Manual - Page 8
Browse online or download pdf Manual for Industrial Equipment Siemens SIMATIC RTLS PCB OEM PULSE. Siemens SIMATIC RTLS PCB OEM PULSE 11 pages. Localization systems
Also for Siemens SIMATIC RTLS PCB OEM PULSE: Operating Instructions Manual (20 pages)
2 Technical specifications
2.1 Connections and supply voltage
Connections and supply voltage
Voltage
Energy intake
2.2 Wireless
Wireless PULSE (localization)
Wireless process
Transmission speed
Frequency range
Bandwidth
Transmit power
Antenna
Range
2.3 Environment
Environment
PCB dimensions
Antenna dimensions
Weight
Temperature range
Method of securing
8
3.3 V DC (±100 mV)
Max. 0.3 A
IEEE 802.15.4-2011 UWB
850 Kbps
The following frequency bands are supported:
4000 MHz
•
6500 MHz
•
500 MHz
0.037 mW
Connected via antenna cable
Inside maximum 90 m (typical 60 m),
Outside maximum 1000 m (typical 500 m)
44 x 24 x 7.5 mm
38 x 20 x 3 mm
Approx. 10 g
0 to +50 ℃
PCB: 3 screws, Ø 1.7 mm
Antenna: provided by customer
SIMATIC RTLS PCB OEM PULSE
Manual, 10/2018, C79000-G8976-C552-01