Technical specifications
Table 4- 1
Technical specifications of the gateway RTLS4030G
Product name
PULSE radio frequencies
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
PHASE radio frequencies
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
Ethernet
Transmission speed
Duplex mode
DHCP
PoE
SIMATIC RTLS4030G
Operating Instructions, 06/2020, C79000-G8976-C515-03
6GT2701-5DB03, 6GT2701-5DB13
SIMATIC RTLS4030G
IEEE 802.15.4-2015 UWB HRP PHY
850 kbit/s
3993.6 MHz (UWB channel 2; CE, FCC/NOM)
6489.6 MHz (UWB channel 5; CE, FCC/NOM, CMIIT)
499.2 MHz
3100 MHz ... 4800 MHz (CE, FCC/NOM)
6000 MHz ... 7000 MHz (CE, FCC/NOM, CMIIT)
0.037 mW (-41.3 dBm/MHz)
Maximum 30 m
0.2 m
Built-in UWB antenna
IEEE 802.15.4
1 Mbit/s
2400 ... 2480 MHz ISM band
2 MHz; data transmission on 802.15.4; channels configura-
ble
2400 MHz ... 2483.5 MHz
0.022 ... 100 mW
Maximum 500 m
1 m
Built-in 2.4 GHz antenna
10 / 100 Mbit/s
Half or full duplex
Yes
IEEE 802.3af
Class 0. power rating 0.44 ... 12.94 W
4
6GT2701-5DB23
21