3.3.1 Power supply

When connecting the power supply to the power connector, all LEDs flash for an instant. The
power LED is on, if power is supplied (cf. states of the LEDs 2.2.1).
The device can be powered via Ethernet cable. In this case the power supply connector should
be sealed to avoid ingress of moisture.
Do not supply the device by power input and PoE at the same time.
Check whether the nominal voltage of the power supply is in accordance with the values stated
in section "Technical data" (cf. 5).
CAUTION
The power supply for the device should not exceed the following values:
U < 30 V; I < 3.3A; P < 100 W

3.3.2 Ethernet

Mind the relevant general conditions and their legal basis when installing and connecting the
Ethernet line.
Connect the Ethernet cable to the appropriate socket. Assemble the Ethernet cable into the
RJ45 jack beforehand.
To supply the device Power over Ethernet (PoE) an appropriate infrastructure such as PoE-
Iniector or PoE-Switch is necessary.

3.4 Operation

The device is not designed for use in EX-zones.
Operation of the system in accordance with regulation EN 60950-1 is only safeguarded insofar
as the case-cover is mounted (cooling, fire protection, disturbance suppression).
Break the circuit connecting the device in case of emergencies (e.g. damaged housing,
intrusion of liquids or foreign objects) and notify the service immediately.

3.5 Cleaning and maintenance

The device may only be opened by appropriately trained and qualified personnel.
Repairs may exclusively be carried out by authorized service points.
Unauthorized opening and improper repairs of the device can cause substantial dangers for the user.
Agilion GmbH's warranty and liability are void in case of unauthorized opening of the device.
Never use abrasive, alkaline or aggressive cleaning agents or auxiliary devices when cleaning the
housing.
SIMATIC RTLS4030G
Device manual, 10/2018, C79000-G8976-C515-01
11