Power supply
When the power supply is connected to the power plug, all LEDs flash briefly for a moment.
The POWER LED lights up as soon as voltage is present.
You can supply the gateway with power via the Ethernet cable. In this case, the power plug
must be tightly sealed to prevent moisture from penetrating. The gateway has Class 0
according to PoE.
NOTICE
No simultaneous power supply
Do not supply the gateway with power through the power plug and the PoE connection at
the same time.
Check whether the rated voltage of the power supply corresponds to the values in the section
"Technical specifications (Page 25)".
Installation without holder
The screws and anchors are not supplied with the device.
Follow these steps to mount the gateway without holder to the wall:
1. Draw the bore holes on the wall according to the following drilling pattern.
2. Drill the holes with a suitable tool.
3. Insert the suitable anchors in the holes.
4. Mount the gateway to the wall using screws (M4).
Figure 3-1
SIMATIC RTLS4030G
Operating Instructions, 05/2023, C79000-G8976-C515-10
Drilling pattern - All dimensions specified in millimeters
Installation & Operation
3.1 Notes on installation