4 Technical data
4.1 Radio
Radio PULSE (Location)
Wireless technology
Frequency range
Output power
Antenna
Radio PHASE (Communication and optional location)
Wireless technology
Frequency range
Output power
Band width
Antenna
4.2 Power supply
Power supply
Energy supply
Service life (at 20 °C) Standby: 1 year
SIMATIC RTLS4030T
Device manual, 06/2019, C79000-G8976-C520-02
IEEE 802.15.4-2011 UWB
3100 MHz ... 4800 MHz
6000 MHz ... 7000 MHz
0.037 mW (-41.3 dBm/MHz)
UWB antenna (built-in)
IEEE 802.15.4
2.40 ... 2.48 GHz ISM-Band
Max. 4 dBm (adjustable)
2 MHz; Data transmission via 802.15.4 channels (adjustable)
2.4 GHz antenna (built-in)
VARTA 3 V Lithium CR123A battery (1550 mAh)
Active time: 100% UWB-location at 1 sec: 6 months