Technical specifications

Table 4- 1
Technical specifications of the RTLS4040T transponder
Product name
PULSE radio frequencies (localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
PHASE radio frequencies (communication and optional localization)
Wireless method
Transmission speed
Operating frequency rated value
Bandwidth
Frequency range
Transmit power
Range
Accuracy of the localization (typical)
Antennas
Supply voltage, power consumption
Supply voltage
Operating time of a full battery charge (at 20 °C)
Permitted ambient conditions
Ambient temperature
During operation
During storage
During transport
During charging
SIMATIC RTLS4040T
Operating Instructions, 05/2023, C79000-G8976-C596-04
SIMATIC RTLS4040T
IEEE 802.15.4-2015 UWB HRP PHY
850 Kbps
3993.6 MHz (UWB channel 2; CE)
6489.6 MHz (UWB channel 5; CE)
499.2 MHz
3100 MHz ... 4800 MHz (CE)
6000 MHz ... 7000 MHz (CE)
0.037 mW (-41.3 dBm/MHz)
Maximum 50 m
0.1 m
Built-in UWB antenna
IEEE 802.15.4
1 Mbit/s
2400 ... 2480 MHz ISM band
2 MHz; data transmission on 802.15.4; channels
configurable
2400 MHz ... 2483.5 MHz
Maximum 12.6 mW (configurable)
Maximum 500 m
3 m
Built-in 2.4 GHz antenna
3.7 V lithium ion rechargeable battery (1900 mAh)
Approx. 1 day
-10 ... +50 °C
-10 ... +50 °C
-10 ... +50 °C
+10 ... +40 °C
4
6GT2700-5DA03