Also for Siemens SINAMICS G130: Operating Instructions Manual (24 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (31 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (22 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (34 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (42 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (42 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (22 pages), Operating Instructions Manual (24 pages)

Siemens SINAMICS G130 Operating Instructions Manual
Components
The article numbers of the individual components (dv/dt reactor and Voltage Peak Limiter)
are listed in the following table:
Table 2- 4
dv/dt filter plus Voltage Peak Limiter, article number of the individual components
dv/dt filter plus Voltage Peak Limiter
6SL3000-2DE32-6AA0
6SL3000-2DE35-0AA0
6SL3000-2DE38-4AA0
6SL3000-2DE41-4AA0
6SL3000-2DH31-0AA0
6SL3000-2DH31-5AA0
6SL3000-2DH32-2AA0
6SL3000-2DH33-3AA0
6SL3000-2DH34-1AA0
6SL3000-2DH35-8AA0
6SL3000-2DH38-1AA0
Limiting the rate of voltage rise and the voltage peaks by means of the motor reactor and dv/dt filter
plus Voltage Peak Limiter
IGBT converter switching frequencies result in high voltage gradients (dv/dt) at the converter
output. If long motor cables are used, this leads to an additional current load on the
converter due to capacitive charge/discharge currents. The high voltage gradients, and the
resulting transients at the motor terminals, cause the motors' electrical winding load to
increase as compared with direct on-line operation.
The dv/dt filter plus Voltage Peak Limiter limits the rate of voltage rise to values < 500 V/µs
and the typical voltage peaks Û
m):
● < 1000 V at U
● < 1250 V at 660 V ≤ U
dV/dt filter plus Voltage Peak Limiter
Operating Instructions, 11/2017, A5E00692302A
dv/dt reactor
Line voltage 3 AC 380 V ... 480 V
6SL3000-2DE32-6CA0
6SL3000-2DE35-0CA0
6SL3000-2DE38-4CA0
2 x 6SL3000-2DE41-4DA0
Line voltage 3 AC 500 V ... 600 V and 3 AC 660 V ... 690 V
6SL3000-2DH31-0CA0
6SL3000-2DH31-5CA0
6SL3000-2DH32-2CA0
6SL3000-2DH33-3CA0
6SL3000-2DH34-1CA0
6SL3000-2DH35-8CA0
2 x 6SL3000-2DH38-1DA0
LL
≤ 575 V
line
≤ 690 V
line
to the following values (with motor cable lengths of ≤ 150
Voltage Peak Limiter
6SL3000-2DE32-6BA0
6SL3000-2DE35-0BA0
6SL3000-2DE38-4BA0
6SL3000-2DE41-4BA0
6SL3000-2DH31-0BA0
6SL3000-2DH31-5BA0
6SL3000-2DH32-2BA0
6SL3000-2DH33-3BA0
6SL3000-2DH34-1BA0
6SL3000-2DH35-8BA0
6SL3000-2DH38-1BA0