Also for Siemens SINAMICS G130: Operating Instructions Manual (24 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (31 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (22 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (34 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (26 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (42 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (30 pages), Operating Instructions Manual (42 pages), Operating Instructions Manual (46 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (22 pages), Operating Instructions Manual (24 pages)

Siemens SINAMICS G130 Operating Instructions Manual
Table 3- 3
Dimensions of dv/dt reactor, line voltage 3-phase 500 - 600 VAC and 660 - 690 VAC, Part 2 (all values in mm)
6SL3000-
a2
a3
a4
a5
a6
a7
a8
I4
I5
hmax
h2
h3
n1
1)
n2
1)
n3
n4
d3
Lengths n1 and n2 correspond to the drill hole spacing
1)
Dimension drawing of the Voltage Peak Limiter
Table 3- 4
dV/dt filter plus Voltage Peak Limiter
Operating Instructions, 11/2017, A5E00692302A
2DH34-1CA0
2DH35-8CA0
30
6
17
14 x 18
11
-
-
460
152.5
385
280
83
212
356
312
78
M12 (15 x 22)
M12 (15 x 22)
Assigning Voltage Peak Limiters to dimension drawings
Voltage Peak Limiter
Line voltage 3-phase 380 – 480 VAC
6SL3000-2DE32-6BA0
6SL3000-2DE35-0BA0
6SL3000-2DE38-4BA0
6SL3000-2DE41-4BA0
Line voltage 3-phase 500 - 600 VAC and 660 - 690 VAC
6SL3000-2DH31-0BA0
6SL3000-2DH31-5BA0
6SL3000-2DH32-2BA0
6SL3000-2DH33-3BA0
6SL3000-2DH34-1BA0
6SL3000-2DH35-8BA0
6SL3000-2DH38-1BA0
2DH38-1DA0
40
8
22
14 x 18
14 x 18
11
-
-
460
152.5
385
280
78
212
356
312
78
M12 (15 x 22)
Mechanical installation
50
8
16
11
14
22
445
145
385
255
114
212
341
312
78
Dimension drawing type
Type 1
Type 2
Type 3
Type 3
Type 1
Type 1
Type 2
Type 2
Type 3
Type 3
Type 3
19