Also for Siemens SINAMICS S120: Operating Manual (20 pages), Getting Started (32 pages), Manual (41 pages), Short Description (22 pages), Manual (43 pages), Applications Manual (34 pages), Applications Manual (46 pages), Operating Instructions Manual (22 pages), Getting Started (32 pages), Operating Instructions Manual (21 pages), Engineering Manual (30 pages), Commissioning Manual (20 pages)

Siemens SINAMICS S120 Instruction For Installation In Cabinets For Marine Drive Applications
10

Dimensional diagrams of Active Interface Modules

The Active Interface Module consists of two components, i.e. of the filter choke and
the filter module. Table 15 shows the dimensional diagram of the filtwer choke of size
JIL. From the dimensional diagrams also the position of the fixing holes can be taken.
More, and more detailed information will be found in the relevant equipment manual
Sinamics S120 Power units / Chassis / Liquid-cooled.
Table 15: Dimensional diagram of the filter choke of the Active Interface Module Size JIL
Dimensions of filter chokes (in mm)
6SL3005-
B
H
T
Type of
connection
Instruction for installation of the liquid-cooled chassis of Sinamics S120 power units into cabinets for marine drive applications,
12/2016, 4BS0808-003
0DE38-4AA0
0DE41-4AA0
349
382
700
698
<575
<575
Type 1
Type 1
Dimensional diagrams of Active Interface Modules
0DG37-4AA0
0DG41-3AA0
358
675
<575
Type 1
0DG41-6AA0
440
440
705
705
<575
<575
Type 2
Type 2