Also for Siemens SINAMICS S120: Operating Manual (20 pages), Getting Started (32 pages), Manual (41 pages), Short Description (22 pages), Manual (43 pages), Instruction For Installation In Cabinets For Marine Drive Applications (28 pages), Applications Manual (46 pages), Operating Instructions Manual (22 pages), Getting Started (32 pages), Operating Instructions Manual (21 pages), Engineering Manual (30 pages), Commissioning Manual (20 pages)

Siemens SINAMICS S120 Applications Manual
Marine-specific installation regulations
8.2 Integration of the components in the cabinet
Figure 8-3
Note
Integrating a Power Module into the control cabinet
• The distance between the control cabinet base and the top of the chassis should not
exceed 1700 mm.
• Power Modules, frame sizes FSD, FSE, FSF and FSG, should be arranged centered
(widthwise) in the control cabinet.
• The drilling patterns for the mounting plate can be taken from the standard
documentation.
28
Control Unit Adapter Kit and separately installed Control Unit
Using SINAMICS G120 / G120C / S120 Blocksize converters in marine applications
Application Manual, 11/2019, A5E48346362A