3.3
Connecting the interfaces on the PPU
3.3.1
Digital input interfaces - X100, X101, X102
Type
Cable
Inputs
Table 3- 1
Illustration
Electrical Installation Manual
Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0
Mini Combicon 10-pin
Max. length: 10 m
Max. cross-section:
One cable per connection: ≥ 0.5 mm2
Permissible level (including ripple)
High level: 18 V - 30 V
Low level: -3 V - +5 V
Pin assignment of X100 (DIN0)
Pin
Signal
1
N.C.
2
I0.0
3
I0.1
4
I0.2
5
I0.3
6
I0.4
7
I0.5
8
I0.6
9
I0.7
10
M
3.3 Connecting the interfaces on the PPU
Comment
Not assigned
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
Digital input
External ground
Connecting
19