Connecting
3.3 Connecting the interfaces on the PPU
Connection cables
End sleeves are necessary if you use two cables per connection.
Fasten the cables to the screw terminals and plug the terminal into the interface X21.
You can buy the shielded cables from a third-party manufacturer.
3.3.4
Distributed I/O - X301, X302
Pin assignment
Type
Inputs
Outputs
24
50-pin socket
Permissible level (including ripple)
High level: 18 V - 30 V
Low level: -3 V - +5 V
Rated digital output current: 250 mA
Electrical Installation Manual
Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0