Siemens SIWAREX WL280 Operating Instructions Manual - Page 27
Browse online or download pdf Operating Instructions Manual for Industrial Equipment Siemens SIWAREX WL280. Siemens SIWAREX WL280 42 pages. Pressure piece sets rn-s sa
5.2.7
Checking the installation
Procedure
NOTICE
Destruction of the load cell and the pressure piece set
Check that the load cell and pressure piece set are installed correctly, e.g. by checking the
mounting dimensions and oscillation distances. Incorrect assembly can lead to the
destruction of the load cell and the pressure piece set.
Check the installation of the load cell:
1. The load bearing implement must be able to oscillate freely.
2. The pendulum support should be aligned as vertically as possible.
RN-S SA
Operating Instructions, 09/2013, A5E32962759A-01
5.2 Mounting the pressure piece set
Installation
27