Siemens 540-717 Installation Instructions Manual
Browse online or download pdf Installation Instructions Manual for Controller Siemens 540-717. Siemens 540-717 8 pages. Room pressurization controller –
pneumatic output and with autozero
modules
Also for Siemens 540-717: Installation Instructions Manual (7 pages)
Room Pressurization Controller – Pneumatic
Output
P P P P r r r r odu
oduc c c c t t t t D D D D e e e e s s s s c c c c r r r r i i i i p p p p t t t t i i i i on
on
odu
odu
on
on
These instructions explain how to field install (pages 1
through 3) or replace (pages 3 through 4) a Room
Pressurization Controller – Pneumatic Output with or
without Autozero Modules.
P P P P r r r r odu
oduc c c c t t t t N N N N u u u u m m m m be
ber r r r
odu
odu
be
be
540-716
Room Pressurization Controller –
Pneumatic Output
540-717
Room Pressurization Controller –
Pneumatic Output with Autozero
Modules
Shipping carton includes a pre-assembled metal
enclosure with controller board and cover, pneumatic
output modules, Autozero Modules with brackets
(optional), and four self-tapping/drilling screws.
I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on
on
on C C C C on
on
on
onv v v v en
on
en
ent t t t i i i i on
en
C C C C A A A A U U U U T T T T I I I I O O O O N N N N : : : :
R R R R equ
equ
equ
equi i i i r r r r ed
ed T T T T oo
ed
ed
oo
ools ls ls ls
oo
•
Electro-Static Discharge (ESD) wrist strap
•
Small flat-blade screwdriver
•
Medium flat-blade screwdriver
•
Medium-duty electric drill
•
1/4 in. (6.35 mm) hex nut bit
•
Portable Operator's Terminal with Controller
Interface Software Rev. 2.0 or higher (required
for controller replacement only)
Additional tools needed if not using self-tapping
option:
•
1/4 in. (6.35 mm) hex nut driver
•
1/8 in. (3 mm) bit
ons s s s
on
on
Equipment damage or loss
of data may occur if the user
does not follow procedure
as specified.
P P P P r r r r e e e e r r r r equ
equisi isi isi isit t t t e e e e s s s s
equ
equ
•
Room temperature sensor installed (optional)
•
Air velocity sensors installed in ducts
•
A source of 24 Vac Class 2 power available
•
Supply power to the unit is OFF
•
An air supply line is available at the controller
E E E E x x x x pe
pec c c c t t t t ed
pe
pe
ed I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on
ed
ed
on
on
on T T T T i i i i m m m m e e e e
New controller installation
Replacement (old controller has
removable terminal blocks)
Replacement (old controller
does not have removable
terminal blocks)
N N N N O O O O T T T T E E E E : : : : You may require additional time for database
work at the field panel.
N N N N e e e e w w w w I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on
on I I I I n n n n s s s s tr tr tr tru u u u c c c c t t t t i i i i on
on
on
N N N N O O O O T T T T E E E E : : : : These steps only refer to new installations.
For replacement instructions, refer to pages 3-4. For
Autozero Module installation, refer to instruction 540-
199.
The following tasks can be performed by the
electrician:
1. Loosen, but do not remove, the cover screws and
remove the enclosure cover. Using the rear panel
of the enclosure as a template (Figures 1 and 2),
mark the location for the four screw holes where
you will install the enclosure.
2. Do one
one of the following:
one
one
•
I I I I f f f f u u u u s s s s i i i i ng
ng t t t t he
ng
ng
he
he
he s s s s e e e e l l l l f f f f - - - - t t t t a a a a pp
drill and the hex nut bit, start the screws.
(Screws do not require starter holes.)
•
I I I I f f f f no
not t t t u u u u s s s s i i i i ng
no
no
ng t t t t he
ng
ng
he s s s s e e e e l l l l f f f f - - - - t t t t a a a a pp
he
he
1/8 in. (3 mm) pilot holes for the screws.
Using the hex nut driver, start the screws.
I I I I n n n n s s s s t t t t a a a a ll ll ll lla a a a t t t t i i i i on on on on I I I I n n n n s s s s t t t t r r r r u u u u c c c c t t t t i i i i on on on ons s s s
Document No. 540-219
Rev. 2, January, 1999
10 Minutes
6 Minutes
16 Minutes
ons s s s
on
on
pp
ppi i i i ng
pp
ng
ng
ng s s s s c c c c r r r r e e e e w w w w s s s s : : : : Using the
ppi i i i ng
pp
pp
ng
ng s s s s c c c c r r r r e e e e w w w w s s s s : : : : Drill four
ng
P P P P a a a a ge
ge 1 1 1 1 o o o o f f f f 8 8 8 8
ge
ge