Also for Cisco 3905: User Manual (14 pages), User Manual (40 pages), User Manual (2 pages), User Manual (3 pages), Features (6 pages), User Manual (40 pages), Features (11 pages), User Manual (36 pages), Quick Reference Manual (2 pages), Using Manual (16 pages), User Manual (2 pages), (Portuguese) Quick Start Manual (1 pages)

Cisco 3905 User Manual
3001736-EFC21-EFC25-UK

4. Daily use

A
D
Fig.12
Using the remote control
with the EFC25
• Press ON/OFF button (Fig. 12-B) and the Burner button (Fig. 12-D) for at least a second to ignite
the fire.
• Operating LED (Fig. 12-E) will flash GREEN until the correct chimney draught is achieved. If the
LED flashes YELLOW, then the Air inlet must be opened and the fire will ignite.
• If it is available, then the flame HIGH/LOW function can be selected using the HIGH/LOW button
(Fig. 12-C). The operating LED will blink once for LOW and twice for HIGH.
• The fan speed is adjusted using the speed buttons (Fig. 12A and D) while the operating LED
flashes. Fan speed cannot be set lower than the pre-set safety minimum.
• To switch off press the ON/OFF button again (Fig. 12-B).
• The ventilation function can be activated by pressing the ON/OFF button on the remote control
(Fig. 12-B) for five seconds The operating LED will be YELLOW when the function is active.
Using the
EFC controller
• Press the ON/OFF button (Fig. 12-F).
• The operating LED (Fig. 12-E) will flash GREEN until the correct chimney draught is confirmed.
If it flashes YELLOW, then the Air inlet must be opened The operating LED will then become
GREEN and the fireplace can be lit.
• To stop the fan press the ON/OFF button.
External ON/OFF switch
• The ON/OFF switch can be used to start, stop and reset the controller.
• If the external ON/OFF switch is used, it has priority over the control panel and the remote
control.
NB
The switch must be in the OFF position before the controller can be re-started.
E
B
C
G
F
UK 11