Levelling
Align the appliance using a spirit level.
Incorrect alignment may result in loud
noises, vibrations and machine
"movement".
Loosen the lock nuts using a WAF17
1.
spanner, by turning it in a clockwise
direction.
Check the alignment of the washing
2.
machine with a spirit level, and
adjust it if necessary. Change the
height by turning the appliance feet.
All four appliance feet must stand
firmly on the ground.
The lock nuts on all four appliance
3.
feet must be screwed tightly against
the housing using a suitable WAF17
spanner. In doing so, hold the foot
tight and do not adjust its height.
Electrical connection
:
Warning
Danger of death!
There is a risk of electric shock if you
touch live components.
Never touch or hold the mains plug
■
with wet hands.
Only pull out the mains cable by the
■
plug and never by the cable, as this
could damage it.
Never unplug the mains plug during
■
operation.
Positioning and connecting
Observe the following information and
ensure that:
Notes
The mains voltage and voltage
■
indicated on the washing machine
(rating plate) are the same.
The connected load and fuse
required are specified on the rating
plate.
The washing machine is only
■
connected to an alternating current
supply via a properly installed
earthed socket.
The mains plug fits the socket.
■
The cable cross-section is adequate.
■
The earthing system is properly
■
installed.
The mains cable is only replaced by
■
a qualified electrician (if this is
necessary). Replacement mains
cables are available from customer
services.
No multiple plugs/couplings or
■
extension cables are used.
If an earth-leakage circuit breaker is
■
used, only a type which displays the
z symbol is used.
Only this symbol guarantees
compliance with the currently
applicable regulations.
The mains plug can be accessed at
■
all times. If this is not possible, in
order to comply with the relevant
safety regulations, a switch (2-pole
switch-off) must be built into the
permanent installation in accordance
with electrical installation regulations.
The mains cable is not kinked,
■
squashed, altered or cut through.
The mains cable does not come into
■
contact with heat sources.
en
45