Operating instructions
Burner locations
7
4
5
6
11
1. Medium burner
2. Medium burner
3. Wok burner
Depress control knob and turn anti-clockwise to "High
Burner ignition &
flame"position. Hold the knob down for a few seconds
control
until the flame ignites. Keep control knob depressed for
a few seconds to activate the flame failure device. If
ignition fails, depress knob again and wait for ignition.
Turn anti-clockwise to set the flame to the desired
intensity.
If ignition fails depress knob and try again. If flame is
not established in 15 seconds release the control
knob and open a door and wait 1 minute before
attempting a new ignition procedure.
All burners are fitted with a flame failure device which
shuts off the gas supply if the flame extinguishes for
any reason. To re-ignite, wait 30 seconds for any unburnt
gas to disperse before repeating the ignition procedure
described above.
To turn off the gas supply to a burner turn the control
knob clockwise to the "OFF" position. (Refer Fig.
The control knob is used to adjust the flame of the gas
burner.
"Low flame" graphic= lowest output
"High flame" graphic= higest output
If the ignition sparkers are dirty, this makes the burners
harder to light, so you should keep them as clean
as possible. Clean them using a small brush and
remember that the ignition sparkers must be treated
very gently.
13
1
1
4
2
3
6
4
12
4. Small burner
5. Rapid burner
6. Control Knobs
7. Big wok burner
Burner
Position
Graphic
13
2
3
1 3
)
There are two ways to carry out the connection to the main
gas line:
A. The hotplate can be connected with rigid pipe as
specified in AS5601 table 3.1.
B. Flexible Hose: If installing with a hose assembly, install
with a hose assembly that complies with AS/NZS 1869 (AGA
Approved), 10mm ID, class Bor D, no more than 1,2m long
and in accordance with AS5601. Ensure that the hose does
not contact the hot surfaces of the hotplate, oven, dishwasher
or any other appliance that may be installed underneath or
next to the hotplate. The hose should not be subjected to
abrasion, kinking or permanent deformation and should be
able to be inspected along its entire length with the cooktop
in the installed position. Unions compatible with the hose fittings
must be used and all connections tested for gas leaks.
The supply connection point shall be accessible with the
appliance installed.
WARNING: Ensure that the hose assembly is restrained
from accidental contact with the flue outlet of an under-
bench oven.
Before Leaving- Check all connections for gas leaks with soap
and water. DO NOT use a naked flame for detecting leaks.
Ignite all burners both individually and concurrently to
ensure correct operation of gas valves, burners and ignition.
Turn gas taps to low flame position and observe stability of
the flame for each burner individually and all together. Adhere
the duplicate data plate to an accessible location near the
hotplate.
When
satisfied with the hotplate, please instruct
the user on the correct method of operation. In case the
appliance fails to operate correctly after all checks have
been carried out, refer to the authorised service provider
in your area.
It should be expressly noted that we cannot accept any liability
for direct or indirect damage caused by wrong connection,
leakage or improper installation. When being repaired, the
appliance must always be disconnected from the mains supply;
if required, notify our customer service.