ActronAir Serene 2 RC-02 Operation Manual - Page 12

Browse online or download pdf Operation Manual for Remote Control ActronAir Serene 2 RC-02. ActronAir Serene 2 RC-02 16 pages.

ActronAir Serene 2 RC-02 Operation Manual
Operation Manual

06.03. Quiet Function

1. Press and hold the
indicate it is activated. The compressor will run at a reduced capacity to minimize the operational noise.
NOTE
Due to low compressor frequency operation, this may result in insufficient cooling and heating capacity.
2. Holding
3. Pressing the

06.04. Freeze Protection (FP) Function

In heating operation, the preset temperature of the air conditioner can be set to 8
temperature steady at 8
give the occupant a better head start when they go back home and turn ON the air conditioner.
While the system is in heat mode and 16°C, press the
indoor fan speed with temperature automatically set to 8
or
or
NOTE
The indoor panel and remote control will not indicate 8

06.05. LOCK Function

1. Press and hold the
above the set temperature to indicate that the remote control buttons are locked.
2. Press and hold the
NOTES
When pressing any button, the lock icon will flash to indicate that the remote-control buttons are locked.
All buttons are disabled whilst control has lock function ON.

06.06. BOOST Function

Boost function is available on heating and cooling to accelerate the time it takes to reach the set point.

06.07. ECO/GEAR Function

Press the
button to enter energy efficient mode in the following sequence.
ECO
GEAR (75%)
NOTE
This function is only available under cooling mode.
ECO Operation
1. While in cooling mode, press the
speed to save energy. Energy savings will take effect only when the initial set temperature is below 24°C.
2. If the set temperature is already above 24°C, the fan speed will change to Auto, the set temperature will remain
unchanged.
12
button for more than 2 seconds to activate Quiet Function. Quiet icon will display to
button again for 2 seconds turns off quiet function.
button will also cancel Quiet Mode.
o
C and will prevent the house from freezing when it is unoccupied in severe weather. This will
to cancel this operation.
buttons
Boost
and
buttons for at least 5 seconds to activate lock function. Lock icon will display
Humidity
Boost
and
buttons for 2 seconds to de-activate lock function.
Humidity
GEAR (50%)
Previous setting mode
button. The set temperature will automatically adjust to 24°C Auto fan
Operation Manual - Serene 2 Remote Controller
Document: 9590-4010 Ver. 1 200819
Remote Controller
buttons
twice within 1 second. The unit will operate at high
C and display FP on the indoor unit. Press the
o
C during FP Function.
o
ECO ......
o
C. This will keep the room
or
or