Actulux 111778 Manual - Page 13
Browse online or download pdf Manual for Accessories Actulux 111778. Actulux 111778 20 pages.
Current Limiter and Overload Interrupter
ADVANCED ELECTRONIC CURRENT LIMITER
LIP6 is an advanced electronic product, which is used as a
current limiter between a 24V DC or 48V DC supply and 1 or
2 actuators.
When the adjusted current limit is reached because of
the load of the actuator(s), and the load of the actuator(s)
hereby increased further, the speed of the actuator(s) will
be automatically reduced. This way the consumption will not
exceed the adjusted level, e.g. 3 amp. for 24V or 1,5 amp. for
48V
CONNECTION & SETTINGS
SW
off
1
4A
2
3
4
5
6
FEATURES
Supply: 24VDC or 48VDC +/- 15%
Output: 2 outputs which can function independently (individually in single operation) or or in joint operation (tandem)
Current limiter:
Type of opening system:
SA Power
SA Power
2,5A Rotary 100 / SA Mini
Tandem operation: If one actuator fails, the other one stops shortly after (maximum 3 seconds)
Input resistance: Possibility to connect a 27K ohm resistance over the input clamp connection for monitoring of the line
Dimensions (l x w x h): 100 x 100 x 50 mm
Colour: White RAL 9010 / Density: IP54
Approved according to: EN60335-1 / Marking: CE
intelligent and electronic current limiter
on
Function
Max. current
Motor output
No function
Operation mode
Input resistance
Delay between M1 and M2
Adjustment possibilities for max. current consumption by means of a switch on the board:
24V
48V
3,0A
1,5A
for each actuator output
4,0A
2,0A
for each actuator output
2,5A
1,25A
for each actuator output
LIP6 can work both as single operation, i.e. connected to 1
actuator or as tandem operation i.e. connected to 2 actuators
in parallel operation.
LIP6 has a built in actuator protector. This means that the
voltage will automatically be interrupted if the speed of the
actuator gets relatively very low or stops completely because
of a mechanic locking or end stop. LIP6 is delivered in a
discreet plastic box, which also functions as a link between
the supply and the actuator(s).
OFF
24VDC supply
N/A
48VDC supply
N/A
OFF
on = 2 x Single / off = Tandem
on = 27Kohm connected / off = 27Kohm disconnected
on = delay on
/ off = delay off
- Type LIP6
Settings
ON
OFF
ON
3A
4A
2,5A Rotary 100 / SA Mini
1,5A
2A
2,5A Rotary 100 / SA Mini
OFF
ON
ON
#121333