BATTERIES
Your Utili-Finder
kit will include
• When battery symbol shows
one bar replace batteries.
the following
items...
• The Utili-Finder
locator takes
6 x LR6 (AA)
batteries.
STEP 1: UTILI-GEN
STEP2: UTILI-FINDER
ON
Plug the Utili-Gen
220V AC
into the wall and
switch on the
power.
The green light confirms that power cables can
be traced. The blue light indicates that some
other services can be traced.
STEP 3: SEARCH
STEP 4: MARK
o
• Do not swing the Utili-Finder. Hold at a 90
angle.
• When the bar graph is at the highest point you are
directly over the service and should mark the ground.
• Sweep the floor in a zig zag pattern ensuring the whole
area is covered.
• Joining your marks indicates the path of the service.
• When the visual and audible displays are at their highest
then you are directly over a buried service.
FUNCTIONALITY OF KEYS
i BUTTON
information:
Depress the i button for 2 seconds and release. The Utili-Finder website
address will be displayed, this website provides all online support and
training information.
F BUTTON
Functional test:
Ensure the Utili-Finder and
Utili-Gen are both turned off.
Depress and hold the F button
and turn on the Utilifinder.
• Squeeze trigger
The Utili-Finder will
to turn on
automatically carry
Utili-Finder.
out a functional test.
• LCD activates.
MODE SELECT:
Depress and release the F button
to select the operating mode.
DEPTH READING
Step 1
Position Utili-Finder over the service
Step 2
Ensure Utili-Finder is set to 33 kHz mode
Step 3
Press and release i key for depth reading
PAS means unit is within set tolerances
ERR means unit is outside set tolerances and may need servicing
• Repeat the test in a different location if the unit displays ERR
• The Locator will automatically repeat the function test if it fails
• Repeated failure will indicate a faulty unit, which must be returned for service
Auto
33
kHz
33kHz
(default)
Detects the Utili-Gen signal.
AUTO
Detects all services carrying a detectable signal.
+
33
kHz
metres
i
i
F
safety DireCtions
The symbols used in this manual have the following meanings:
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
DANGER
Indicates a potentially hazardous situation or an unintended use which, if not avoided, could result in death or serious injury.
WARNING
W
Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor or moderate injury and/or
CAUTION
appreciable material, financial and environmental damage.
C
Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and
efficient manner.
The following directions should enable the person responsible for the product, and the person who actually uses the equipment, to anticipate and
avoid operational hazards.
PermitteD use: The products are intended to be used for the detection and localization of underground metallic services: cables and metallic pipes. Utili-Gen is for
indoor use only.
rePair: The products contain no user serviceable parts and do not require regular maintenance. Only Utili-Finder authorised service workshops are entitled to repair
these products.
Do not
• Use products with obviously recognizable damage or defects
• Connect Utili-Gen to a electrical socket with recognizable damage or defects or when wet
• Open or modify the product using tools, for example screwdriver
• Disable electrical equipment safety systems
• Remove hazard notices
HazarDs of use
High mechanical stress, high ambient temperatures or immersion into fluids can cause leakage, fire or explosions of the batteries.
WARNING
Precautions: Protect the batteries from mechanical influences and high ambient temperatures. Do not drop or immerse batteries into fluids.
During the transport, shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard.
C CAUTION
Precautions: Before shipping the product or disposing of it, discharge the batteries by running the product until they are flat.
The depth reading might not reflect the real depth when the Utili-Finder picks up the signal induced into the service by the Utili-Gen. This signal is
radiated from the centre of the service, readings with larger diameter pipes will read shallow.
WARNING
Precautions: Always compensate depth reading for service size.
C
The absence of a positive indication does not guarantee the non-existence of a service.
Services without a detectable signal may be present.
CAUTION
The Utilifinder cannot locate non-metallic services such as plastic pipes, typically used by the water and gas utilities.
Precautions: Always excavate with care.
When transporting or shipping batteries, the person in charge of the product must ensure that the applicable national and international rules and regulations are
observed. Before transportation or shipping contact your local passenger or freight transport company.
DisPosal
The product must not be disposed with household waste. Dispose of the product appropriately in accordance with the national regulations in
force in your country.
Always prevent access to the product by unauthorised personnel.
If the product is improperly disposed of, the following can happen:--
WARNING
• If polymer parts are burnt, poisonous gases are produced which may impair health
• If batteries are damaged or are heated strongly, they can explode and cause poisoning, burning, corrosion or environmental contamination
C
• By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations, exposing themselves and third parties
to the risk of severe injury and rendering the environment liable to contamination
• Improper disposal of silicone oil may cause environmental contamination
Precautions: Product specific treatment and waste management information can be downloaded from the Utili-Finder website at www.utilifinder.com or received
from your Utili-Finder dealer.
eleCtromagnetiC ComPatibility emC
The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and
electrostatic discharges are present, and without causing electromagnetic disturbances to other equipment.
eleCtromagnetiC raDiation Can Cause DisturbanCes in otHer equiPment.
WARNING
Although the product meets the strict regulations and standards which are in force in this respect, the manufacturer cannot completely exclude the
possibility that other equipment may be disturbed.
labelling:
C
utili-finDer
utili-gen
Type:
S.No.:
Cable Detection Ltd.
Power:
Stoke On Trent
6x LR6(AA) Alkaline
Staffordshire
9V
nominal / 200mA max.
Made in the UK
NOTICE
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference