Argo DD Installation Instructions Manual - Page 10
Browse online or download pdf Installation Instructions Manual for Air Conditioner Argo DD. Argo DD 16 pages. Air conditioner without outdoor unit
ON/OFF CONTACT CONNECTION
The air conditioner is equipped with an ON / OFF contact
EN
(in very low voltage, to be connected to a clean contact, not
in tension); When opening the contact, the air conditioner
is in stand-by.
Through this contact it is possible to connect an external
device that inhibits the operation of the air conditioner,
as for example: window opening contact, remote on / off,
infrared presence sensor, enabling badge, etc.
It is recommended to use a double insulation cable.
The unit is supplied with a pre-installed jumper between
2 poles of the terminal block; remove the jumper before
connecting the remote ON / OFF contact.
3.3 - HOW TO MOUNT THE FRONT PANEL AND THE
BOTTOM PANEL WITH FILTER
Mount the front panel taking care not to scratch it; operate
as follows:
- Connect the receiver cable to the connector (1).
- Grasp the panel, keeping it slightly raised relative to the
unit and bring it into place by inserting it first right and
then left. (See figure)
- Slide it down in order to fix the three lateral hooks (2) to
the structure.
CAUTION
- Loosen the screws of the two lower safety hooks (2),
move them outwards and re-tighten them again to
secure the panel, so that it is not accidentally removable.
- At this point mount the bottom panel with filter (see
figure) as follows:
- Place the panel vertically and insert it under the unit on
the back so that the four hooks (3) fit into place.
- Rotate the panel upwards to fix the front part to the
structure through the central hooks (4); help yourself
by pressing the central hooks with two fingers.
Once the installation is finished, verify the correct operation
of the air conditioner.
2
2
3
3
BOTTOM PANEL WITH FILTER
10
1
2
4
4
3
3
3