DigiTech XC-0328 User Manual - Page 6
Browse online or download pdf User Manual for Weather Station DigiTech XC-0328. DigiTech XC-0328 8 pages. Wireless indoor / outdoor 8-channel thermo-hygrometer with jumbo display
1.
Electro-Magnetic
lnterference
(EMl).
Keep
the
console several
feet
away from computer monitors and TVs.
2.
Radio Frequency Interference (RFl).
lf
you
have other
433
MHz devices and communication is intermittent, try turning off
these other devices
for
troubleshooting purposes.
You
may
need
to
relocate
the
transmitters
or
receivers
to
avoid
intermittent communication.
3. Line of Sight
Rating. This device is rated at 90 meters line of
sight
(no interference, barriers or
walls)
but
typically
you
will
get
30 meters maximum under most real-world
installations, which
include passing through barriers or walls.
4.
Metal Barriers.
Radio frequency
will not
pass through
metal
barriers
such
as
aluminum
siding.
lf
you have
metal
siding,
align
the
remote and console through a window
to
get
a
clear
line of
sight
.
5.6 Adjustment or Calibration
_--
Note: The
calibrated
value
can
only
be adiusted on
the
console.
The
remote
senso(s)
always displays
the
un-calibrated
or
measured
value.
- -
Note: The
measured humidity range
is
between 10
and
99%.
Humidity cannot be accurately measured outside
of
this
range.
The
purpose of calibration is to fine
tune
or correct
for
any sensor
error
associated with the devices
margin
of
error.
The
measurement
can
be
adjusted from
the
console
to
calibrate to a known source.
Calibration
is
only useful
if
you have
a
known calibrated source
you
can
compare
it
against,
and
is
optional.
This
section
discusses
practices, procedures
and
sources
for
sensor calibration
to
reduce
manufacturing and degradation errors. Do not compare your
readings
obtained
from
sources
such
as the
internet,
radio'
television
or
newspapers.
They are in a different
location
and typically update
once
per hour.
The
purpose of your weather station
is
to
measure conditions of
your
surroundings, which vary significantly from location to location.
5.6.1 HumidityCalibration
Prior to entering
the
calibration mode, press
the CHANNEU+
button to
select the humidity sensor you wish to adjust.
To enter
the
humidity calibration mode, press
and hold
the
ADJUST
and
MIN/MAX buttons at
the
same time
for
5 seconds
and the
humidity
value
will
begin
flashing.
Press the
CHANNEL/+
button
to
increase
the
humidity and
the
MIN/MAX/- button
to
decrease
the
humidity reading
in
1% increments.
To
rapidly
increase (or decrease)
the
humidity reading, press and hold
the
CHANNEL/+
or
MIN/MAX/- button.
To
return
the
humidity
to the
actual
or
uncalibrated measurement,
press the
ADJUST
button.
Once
the displayed humidity equals the calibrated source,
press
and hold the
ADJUST button
for
three
seconds,
or
wait
15
seconds for
timeout,
and
the
humidity value
will
stop
flashing.
5.6.2
Temperature
Calibration
Prior
to
entering
the calibration
mode, press
the CHANNEU+
button to
select the temperature you wish
to
adjust.
To
enter
the
temperature calibration mode,
press
and
hold
the
ADJUST
butlon
for
5
seconds
and
the temperature value
will
begin
flashing. Press
the
CHANNEU+ button
to
increase
the
temperature
and
the
MIN/MAX-
button
to
decrease
the
temperature reading
in
0.1'C
increments. To rapidly increase
(or
decrease)
the
temperature
reading, press
and
hold
the CHANNEL/+
or
MIN/MAX-
button.
To return the temperature
to
the actual
or
uncalibrated
measurement,
press the
ADJUST
button.
Once
the
displayed temperature equals
the
calibrated source,
press
and
hold the
ADJUST
button for
three seconds,
or
wait
15 seconds
for
timeout, and the temperature value will stop flashing.
-'t't-
-1
0-