Argo SLIMMY Operating Instructions Manual - Page 11
Browse online or download pdf Operating Instructions Manual for Air Conditioner Argo SLIMMY. Argo SLIMMY 13 pages.
(3) TEMPERATURE + - AND TIMER ADJUSTMENT BUTTONS
The temperature can be adjusted to between 16 °C and 30 °C.
Increase temperature(+):
1) Allows for adjusting the desired temperature in cooling (COOL) mode.
2)Whenever the(
Decrease temperature (
1) Allows for adjusting the desired temperature in cooling (COOL) mode.
- )
2)Whenever the (
The same button allows for setting the TIMER.
(4) FAN SPEED ADJUSTMENT BUTTON
Press this button when the appliance is switched on for adjusting the ventilation speed in cooling mode (AUTO), to low
(Low), medium (Med) or high (High).
The fan speed cannot be adjusted in DRY mode and is fixed to low speed.
(5)SLEEP BUTTON (on both the remote control and portable unit)
Press this button to activate the Sleep function, which automatically adapts the temperature to changes in body and
room temperature throughout the night, so as to optimise comfort when sleeping and minimise consumption.
In cooling mode, the temperature increases by 1 °C in an hour then by 2 °C in two hours, and remains in this setting for
the whole period. The Sleep function is not available in the ventilation, dehumidification and auto modes. The indicator
light turns on whenever the Sleep function is set.
(6)TIMER BUTTON (on both the remote control and portable unit)
Press and hold this button for 1 second to set the timer.
1)Timer-on (automatic switch-on)
When the appliance is off, this button is used to set a delay after which the unit will switch on.
Remote control: Press TIMER. The T-ON and H icons will light up on the remote control. Press the + and - buttons
within 5 seconds to set the delay. The T-ON icon will remain on to indicate that the TIMER has been set.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
2)Timer-off (automatic switch-off)
When the appliance is running in the COOL mode, set a delay after which the unit will switch off.
Remote control: Press TIMER. The T-OFF and H icons will light up. Press the + and - buttons within 5 seconds to
set the delay. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm. The T-OFF icon will
remain lit to indicate that the switch-off TIMER is running.
Portable unit: Press TIMER. Select a number of hours from 0.5 to 24. Press the TIMER button to confirm.
Resetting the timer: If a TIMER has been set, press TIMER to display the delay. Press TIMER again to cancel the setting.
(7) X-FAN BUTTON (only on remote control)
By pressing the X-FAN button in the cooling and dehumidification modes, when the unit is switched off the fan
continues to turn for roughly 2 minutes in order to fully dry the evaporator.
(8) TEMPERATURE AND ERROR DISPLAY
Problem
Cause
E5
Overcurrent protection device.
H8
Tank full of water.
F1
Room temperature sensor failure.
F2
Failure of temperature sensor on the
evaporator.
F0
Refrigerant leakage. Air conditioner
out of order.
H3
Overload protection device on
compressor.
E8
Overload protection.
V 12/15
+
) button is pressed, the set temperature increases by 1 °C.
-
):
button is pressed, the set temperature decreases by 1 °C.
Solution
Pull out the plug and insert it again after 10 minutes.
If the problem persists, contact a service centre.
Empty the tank.
If the problem persists, contact a service centre.
Contact a service centre.
Contact a service centre.
Contact a service centre.
The room temperature exceeds the appliance's operating
range (beyond 35°) or there is too much humidity. Wait for
the temperature to drop below 35 °C.
Check if the evaporator and compressor are obstructed by
objects. If they are, remove the objects, disconnect the unit
then restore the power supply.
Clear the obstructed ventilation grilles.
If the problem persists, contact a service centre.
25