Functions

Reset Functions

This camera has the following reset functions for
returning operations to the initial conditions:

• Camera reset

• Camera setting reset
Camera Reset
Reset is executed by accessing the DeviceReset register.
The camera is restarted. This is the same operation as
that when you turn the power off then back on again.

Camera Setting Reset (Initializing)

This reset is executed by holding the reset button on the
rear panel pressed for more than three seconds. Then the
camera is restarted.
The following network settings are returned to their
default values with this reset operation:
Packet size, packet delay, use/nonuse setting of the
persistent IP address and the set values (IP address,
subnet mask, default gateway), use/nonuse setting of
DHCP
In addition, the camera settings are changed as follows:
"UserSetDefaultSelector" is set to "Default."
For More Information Please Call Aegis Electronic Group, Inc. * (888) 687-6877 Phone * [email protected] * http://www.aegis-elec.com

Triggering

Trigger Operations

The camera can shoot images according to trigger
signals supplied from external devices. If no operation
with a trigger signal is selected, the camera performs
free-run image output according to the exposure time
and frame rate settings. In Free-Run mode, the frame
rate is automatically adjusted to the maximum value
according to the exposure time setting. The frame rate
can also be fixed when required. The sensor output
shown in the figures below is a signal (SensorReadOut)
which indicates that the imager output is valid. The
signal can be fed out from the GPIO-OUT connector.
External trigger enabled
Setting parameter: TriggerMode = On
Trigger signal
Exposure
Sensor output
External Trigger disabled/Free Run mode
(Frame Rate Auto adjustment)
Setting parameters: TriggerMode = Off
AcquisitionFrameRateAuto = On
Trigger signal
Exposure
Sensor output
External Trigger disabled/Free Run mode
(Frame Rate fixed)
Setting parameters: TriggerMode = Off
AcquisitionFrameRateAuto = Off
AcquisitionFrameRate = T
Trigger signal
Exposure
Sensor output
Automatically adjusted to
minimize the image interval
1/T
11